Development of a CDC-certified total testosterone assay for adult and pediatric samples using LC-MS/MS.

阅读:5
作者:Star-Weinstock Michal, Dey Subhakar
BACKGROUND: Highly accurate and sensitive method to measure testosterone in hypogonadal male, female and children is vital for proper diagnosis of hormone-related conditions and their treatment. OBJECTIVE: To develop an accurate and robust total testosterone ESI-LC-MS/MS quantification method with a simple sample preparation workflow and sufficient sensitivity for serum or plasma samples of all gender and age groups, via ketone functional group derivatization (using Amplifex™ Keto Reagent). METHOD: A simple sample preparation method to accommodate both low and high numbers of samples was developed using simultaneous protein precipitation and derivatization with Amplifex™ Keto reagent, followed by centrifugation and direct injection of supernatant into an LC-MS/MS system (SCIEX Topaz™ IVD LC-MS/MS, in which MS is equivalent to a SCIEX 4500MD Mass Spectrometer). Total testosterone in human serum or plasma samples was quantified using an external calibration curve generated by calibrators spanning a broad concentration range of ∼1-2000 ng/dL (10-20,000 pg/mL), traceable to NIST 971 SRM. (13)C(3)-enriched testosterone was used as an internal standard to correct for both analyte loss during sample preparation and matrix effect during analysis (Supplementary Information: SI Fig. 4C). Two methods, one using a 96-well filter plate and another using Eppendorf tubes, were developed. Both methods were certified by the Centers for Disease Control (CDC) hormone standardization (HoSt) program for total serum testosterone. The feasibility of implementing the method for plasma and serum samples was tested via a small-scale method comparison study between matched pediatric serum and plasma samples derived from the same donor. In addition, plasma samples originating from the same donor collected in two different anticoagulant tube types (Li-heparin and K(2)EDTA) were compared. RESULTS: Using in-house formulated NIST 971-traceable calibrators, the method was linear (r(2) > 0.999) between 1 and 2000 ng/dL (10 and 20,000 pg/mL) with a limit of detection of approximately 1 ng/dL (10 pg/mL). The testosterone concentration bias against 40 reference samples from the HoSt certification program was absolute <3% with an average %CV of ∼3-4%. More than 78% of samples passed the CDC bias criterion of ±6.4%. Comparison between pediatric matched serum and plasma samples resulted in high correlation (r(2) = 0.997) and bias of <5%. The calculated % difference between matched adult serum and plasma samples was ∼1%. CONCLUSIONS: Feasibility for an accurate and streamlined method suitable for measuring total testosterone in all human samples was demonstrated with a choice of sample preparation workflow to suit low or high number of samples. The method can potentially be used for plasma matrix from different blood collection tubes (Li-Heparin and K(2)EDTA).

特别声明

1、本文转载旨在传播信息,不代表本网站观点,亦不对其内容的真实性承担责任。

2、其他媒体、网站或个人若从本网站转载使用,必须保留本网站注明的“来源”,并自行承担包括版权在内的相关法律责任。

3、如作者不希望本文被转载,或需洽谈转载稿费等事宜,请及时与本网站联系。

4、此外,如需投稿,也可通过邮箱info@biocloudy.com与我们取得联系。