Interlaboratory Comparison of Hydrogen-Deuterium Exchange Mass Spectrometry Measurements of the Fab Fragment of NISTmAb.

阅读:3
作者:Hudgens Jeffrey W, Gallagher Elyssia S, Karageorgos Ioannis, Anderson Kyle W, Filliben James J, Huang Richard Y-C, Chen Guodong, Bou-Assaf George M, Espada Alfonso, Chalmers Michael J, Harguindey Eduardo, Zhang Hui-Min, Walters Benjamin T, Zhang Jennifer, Venable John, Steckler Caitlin, Park Inhee, Brock Ansgar, Lu Xiaojun, Pandey Ratnesh, Chandramohan Arun, Anand Ganesh Srinivasan, Nirudodhi Sasidhar N, Sperry Justin B, Rouse Jason C, Carroll James A, Rand Kasper D, Leurs Ulrike, Weis David D, Al-Naqshabandi Mohammed A, Hageman Tyler S, Deredge Daniel, Wintrode Patrick L, Papanastasiou Malvina, Lambris John D, Li Sheng, Urata Sarah
Hydrogen-deuterium exchange mass spectrometry (HDX-MS) is an established, powerful tool for investigating protein-ligand interactions, protein folding, and protein dynamics. However, HDX-MS is still an emergent tool for quality control of biopharmaceuticals and for establishing dynamic similarity between a biosimilar and an innovator therapeutic. Because industry will conduct quality control and similarity measurements over a product lifetime and in multiple locations, an understanding of HDX-MS reproducibility is critical. To determine the reproducibility of continuous-labeling, bottom-up HDX-MS measurements, the present interlaboratory comparison project evaluated deuterium uptake data from the Fab fragment of NISTmAb reference material (PDB: 5K8A ) from 15 laboratories. Laboratories reported ∼89 800 centroid measurements for 430 proteolytic peptide sequences of the Fab fragment (∼78 900 centroids), giving ∼100% coverage, and ∼10 900 centroid measurements for 77 peptide sequences of the Fc fragment. Nearly half of peptide sequences are unique to the reporting laboratory, and only two sequences are reported by all laboratories. The majority of the laboratories (87%) exhibited centroid mass laboratory repeatability precisions of ⟨ s(Lab)⟩ ≤ (0.15 ± 0.01) Da (1σ(xÌ )). All laboratories achieved ⟨s(Lab)⟩ ≤ 0.4 Da. For immersions of protein at T(HDX) = (3.6 to 25) °C and for D(2)O exchange times of t(HDX) = (30 s to 4 h) the reproducibility of back-exchange corrected, deuterium uptake measurements for the 15 laboratories is σ(reproducibility)(15 Laboratories)( t(HDX)) = (9.0 ± 0.9) % (1σ). A nine laboratory cohort that immersed samples at T(HDX) = 25 °C exhibited reproducibility of σ(reproducibility)(25C cohort)( t(HDX)) = (6.5 ± 0.6) % for back-exchange corrected, deuterium uptake measurements.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。