BACKGROUND: Patient-specific quality assurance (PSQA) is a crucial yet resource-intensive task in proton therapy, requiring special equipment, expertise and additional beam time. Machine delivery log files contain information about energy, position and monitor units (MU) of all delivered spots, allowing a reconstruction of the applied dose. This raises the prospect of phantomless, log file-based QA (LFQA) as an automated replacement of current phantom-based solutions, provided that such an approach guarantees a comparable level of safety. PURPOSE: To retrieve a reliable LFQA conclusion from a one-time plan delivery before treatment initiation, deviations between planned and logged parameters must either be persistent over all following treatment fractions or, in case of random fluctuations, must not have a relevant impact on the reconstructed dose distribution. We therefore investigated the reproducibility of log file parameters over multiple patient treatment fractions and compared the reconstructed dose distributions. METHODS: Log file variability was examined at both spot parameter and integral dose levels. The log files of 14 patient treatment plans were analyzed retrospectively for a total of 339 delivered fractions. From the recorded x/y position and MU parameters per spot, the respective mean difference to the planned value (accuracy) and the standard deviation (reproducibility) were calculated for 108,610 planned spots. The dose distributions reconstructed from the log files of each fraction were evaluated against the planned fraction dose using 3D gamma index analysis. The dose-based gamma pass rate Î was correlated with a new spot-based log file pass rate Î . Beam timing information from the log files was used to quantify the total plan/field delivery time stability after excluding machine interlocks. RESULTS: The mean spot-wise accuracy with respect to distance from planned positions and MUs was (0.6 ± 0.3) mm and (0.0001 ± 0.0023) MU, respectively. The mean reproducibility of the observed single spot deviations was (0.2 ± 0.1) mm and (0.0004 ± 0.0004) MU (mean ± standard deviation). These variations resulted in minimal changes in the reconstructed fraction dose with Î (2 mm/2%) > 99% for all studied fractions. Results for more sensitive criteria Î (1 mm/1%) were plan-specific, but on average > 92.6% per plan and correlated with Î (1 mm) pass rates (0.51 â¤Â r(Pearson) â¤Â 0.99). Field delivery times were reproducible within ± 4 s (2Ï) and no treatment interruptions were observed in 92.8% of cases. CONCLUSIONS: The log file records of plan-relevant spot parameters are well-reproducible over multiple fractions and deviations have no dosimetrically relevant impact on the reconstructed fraction doses. Results of a one-time pre-treatment LFQA are considered as valid for the entire treatment course and there is no concern in this regard to replace state-of-the-art phantom measurements in the current PSQA workflow.
Validity of one-time phantomless patient-specific quality assurance in proton therapy with regard to the reproducibility of beam delivery.
阅读:12
作者:Wolter Lukas Cornelius, Hennings Fabian, Bokor Jozef, Richter Christian, Stützer Kristin
| 期刊: | Medical Physics | 影响因子: | 3.200 |
| 时间: | 2025 | 起止号: | 2025 May;52(5):3173-3182 |
| doi: | 10.1002/mp.17637 | ||
特别声明
1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。
2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。
3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。
4、投稿及合作请联系:info@biocloudy.com。