BACKGROUND: The National Health Laboratory Service is mandated to deliver cost-effective and efficient diagnostic services across South Africa. Their mandate is achieved by a network of laboratories ranging from centralised national laboratories to distant rural facilities. OBJECTIVE: This study aimed to establish a model of CD4 reagent utilisation as an independent measure of laboratory efficiency. METHODS: The efficiency percentage was defined as finished goods (number of reportable results) over raw materials (number of reagents supplied) for 47 laboratories in nine provinces (both anonymised) for 2019. The efficiency percentage at national and provincial levels was calculated and compared to the optimal efficiency percentage derived using pre-set assumptions. Comparative laboratory analysis was conducted for the provinces with the best and worst efficiency percentages. The possible linear relationship between the efficiency percentage and call-outs, days lost, referrals, and turn-around time was assessed. RESULTS: Data are reported for 2 806 799 CD4 tests, with an overall efficiency percentage of 84.5% (optimal of 84.98%). The efficiency percentage varied between 75.7% and 87.7% between provinces, while within the laboratory it ranged from 66.1% to 111.5%. Four laboratories reported an efficiency percentage ranging from 67.8% to 85.7%. No linear correlation was noted between the efficiency percentage, call-outs, days lost, and turn-around time performance. CONCLUSION: Reagent efficiency percentage distinguished laboratories into different utilisation levels irrespective of their CD4 service level. This parameter is an additional independent indicator of laboratory performance, with no relationship with any contributing factors tested, that can be implemented across pathology disciplines for monitoring reagent utilisation. WHAT THIS STUDY ADDS: This study provides an objective methodology to assess reagent utilisation as an independent measure of laboratory efficiency. This model could be applied to all routine pathology services.
Modelling CD4 reagent usage across a national hierarchal network of laboratories in South Africa.
阅读:4
作者:Cassim Naseem, Coetzee Lindi-Marie, Glencross Deborah K
| 期刊: | African Journal of Laboratory Medicine | 影响因子: | 1.200 |
| 时间: | 2023 | 起止号: | 2023 May 15; 12(1):2085 |
| doi: | 10.4102/ajlm.v12i1.2085 | ||
特别声明
1、本文转载旨在传播信息,不代表本网站观点,亦不对其内容的真实性承担责任。
2、其他媒体、网站或个人若从本网站转载使用,必须保留本网站注明的“来源”,并自行承担包括版权在内的相关法律责任。
3、如作者不希望本文被转载,或需洽谈转载稿费等事宜,请及时与本网站联系。
4、此外,如需投稿,也可通过邮箱info@biocloudy.com与我们取得联系。