INTRODUCTION: Unwanted drug interactions with ionic currents in the heart can lead to an increased pro-arrhythmic risk to patients in the clinic. It is therefore a priority for safety pharmacology teams to detect block of cardiac ion channels, and new technologies have enabled the development of automated and high-throughput screening assays using cell lines. As a result of screening multiple ion-channels there is a need to integrate information, particularly for compounds affecting more than one current, and mathematical electrophysiology in-silico action potential models are beginning to be used for this. METHODS: We quantified the variability associated with concentration-effect curves fitted to recordings from high-throughput Molecular Devices IonWorks® Quattro⢠screens when detecting block of I(Kr) (hERG), I(Na) (NaV1.5), I(CaL) (CaV1.2), I(Ks) (KCNQ1/minK) and I(to) (Kv4.3/KChIP2.2), and the Molecular Devices FLIPR® Tetra fluorescence screen for I(CaL) (CaV1.2), for control compounds used at AstraZeneca and GlaxoSmithKline. We examined how screening variability propagates through in-silico action potential models for whole cell electrical behaviour, and how confidence intervals on model predictions can be estimated with repeated simulations. RESULTS: There are significant levels of variability associated with high-throughput ion channel electrophysiology screens. This variability is of a similar magnitude for different cardiac ion currents and different compounds. Uncertainty in the Hill coefficients of reported concentration-effect curves is particularly high. Depending on a compound's ion channel blocking profile, the uncertainty introduced into whole-cell predictions can become significant. DISCUSSION: Our technique allows confidence intervals to be placed on computational model predictions that are based on high-throughput ion channel screens. This allows us to suggest when repeated screens should be performed to reduce uncertainty in a compound's action to acceptable levels, to allow a meaningful interpretation of the data.
Variability in high-throughput ion-channel screening data and consequences for cardiac safety assessment.
阅读:7
作者:Elkins Ryan C, Davies Mark R, Brough Stephen J, Gavaghan David J, Cui Yi, Abi-Gerges Najah, Mirams Gary R
| 期刊: | Journal of Pharmacological and Toxicological Methods | 影响因子: | 1.800 |
| 时间: | 2013 | 起止号: | 2013 Jul-Aug;68(1):112-22 |
| doi: | 10.1016/j.vascn.2013.04.007 | ||
特别声明
1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。
2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。
3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。
4、投稿及合作请联系:info@biocloudy.com。