Problem. Image biomarker analysis, also known as radiomics, is a tool for tissue characterization and treatment prognosis that relies on routinely acquired clinical images and delineations. Due to the uncertainty in image acquisition, processing, and segmentation (delineation) protocols, radiomics often lack reproducibility. Radiomics harmonization techniques have been proposed as a solution to reduce these sources of uncertainty and/or their influence on the prognostic model performance. A relevant question is how to estimate the protocol-induced uncertainty of a specific image biomarker, what the effect is on the model performance, and how to optimize the model given the uncertainty. Methods. Two non-small cell lung cancer (NSCLC) cohorts, composed of 421 and 240 patients, respectively, were used for training and testing. Per patient, a Monte Carlo algorithm was used to generate three hundred synthetic contours with a surface dice tolerance measure of less than 1.18 mm with respect to the original GTV. These contours were subsequently used to derive 104 radiomic features, which were ranked on their relative sensitivity to contour perturbation, expressed in the parameter η. The top four (low η) and the bottom four (high η) features were selected for two models based on the Cox proportional hazards model. To investigate the influence of segmentation uncertainty on the prognostic model, we trained and tested the setup in 5000 augmented realizations (using a Monte Carlo sampling method); the log-rank test was used to assess the stratification performance and stability of segmentation uncertainty. Results. Although both low and high η setup showed significant testing set log-rank p-values (p = 0.01) in the original GTV delineations (without segmentation uncertainty introduced), in the model with high uncertainty, to effect ratio, only around 30% of the augmented realizations resulted in model performance with p < 0.05 in the test set. In contrast, the low η setup performed with a log-rank p < 0.05 in 90% of the augmented realizations. Moreover, the high η setup classification was uncertain in its predictions for 50% of the subjects in the testing set (for 80% agreement rate), whereas the low η setup was uncertain only in 10% of the cases. Discussion. Estimating image biomarker model performance based only on the original GTV segmentation, without considering segmentation, uncertainty may be deceiving. The model might result in a significant stratification performance, but can be unstable for delineation variations, which are inherent to manual segmentation. Simulating segmentation uncertainty using the method described allows for more stable image biomarker estimation, selection, and model development. The segmentation uncertainty estimation method described here is universal and can be extended to estimate other protocol uncertainties (such as image acquisition and pre-processing).
Segmentation Uncertainty Estimation as a Sanity Check for Image Biomarker Studies.
阅读:3
作者:Zhovannik Ivan, Bontempi Dennis, Romita Alessio, Pfaehler Elisabeth, Primakov Sergey, Dekker Andre, Bussink Johan, Traverso Alberto, Monshouwer René
| 期刊: | Cancers | 影响因子: | 4.400 |
| 时间: | 2022 | 起止号: | 2022 Mar 2; 14(5):1288 |
| doi: | 10.3390/cancers14051288 | ||
特别声明
1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。
2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。
3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。
4、投稿及合作请联系:info@biocloudy.com。
