Assessing initial plan check efficacy using TG 275 failure modes and incident reporting.

阅读:4
作者:Riegel Adam C, Polvorosa Cynthia, Sharma Anurag, Baker Jameson, Ge William, Lauritano Joseph, Calugaru Emel, Chang Jenghwa, Antone Jeffrey, Oliveira Angela, Buckenberger Walkiria, Chen William, Cao Yijian, Kapur Ajay, Potters Louis
Plan checks are important components of a robust quality assurance (QA) program. Recently, the American Association of Physicists in Medicine (AAPM) published two reports concerning plan and chart checking, Task Group (TG) 275 and Medical Physics Practice Guideline (MPPG) 11.A. The purpose of the current study was to crosswalk initial plan check failure modes revealed in TG 275 against our institutional QA program and local incident reporting data. Ten physicists reviewed 46 high-risk failure modes reported in Table S1.A.i of the TG 275 report. The committee identified steps in our planning process which sufficiently checked each failure mode. Failure modes that were not covered were noted for follow-up. A multidisciplinary committee reviewed the narratives of 1599 locally-reported incidents in our Radiation Oncology Incident Learning System (ROILS) database and categorized each into the high-risk TG 275 failure modes. We found that over half of the 46 high-risk failure modes, six of which were top-ten failure modes, were covered in part by daily contouring peer-review rounds, upstream of the traditional initial plan check. Five failure modes were not adequately covered, three of which concerned pregnancy, pacemakers, and prior dose. Of the 1599 incidents analyzed, 710 were germane to the initial plan check, 23.4% of which concerned missing pregnancy attestations. Most, however, were caught prior to CT simulation (98.8%). Physics review and initial plan check were the least efficacious checks, with error detection rates of 31.8% and 31.3%, respectively, for some failure modes. Our QA process that includes daily contouring rounds resulted in increased upstream error detection. This work has led to several initiatives in the department, including increased automation and enhancement of several policies and procedures. With TG 275 and MPPG 11.A as a guide, we strongly recommend that departments consider an internal chart checking policy and procedure review.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。