LPS from bovine serum albumin drives TNF-α release during ex-vivo placenta perfusion experiments, contaminates the perfusion system but can be effectively removed by oxidative cleaning

牛血清白蛋白中的 LPS 在体外胎盘灌注实验中会促使 TNF-α 释放,从而污染灌注系统,但可以通过氧化清洗有效去除

阅读:4
作者:T Vasanthan, N Rochow, F Mian, T Codini, B DeFrance, G Fusch, S Samiee-Zafarghandy, C Fusch

Discussion

LPS contamination of the placenta perfusion model could have confounding effects on experimental outcomes leading to misinterpretation of data. To circumvent LPS contamination LPS-free BSA and oxidative depyrogenation cleaning techniques should be implemented in future placental perfusion studies.

Results

TNF-α release, observed in negative control experiments, was attributed to the use of LPS-contaminated BSA as well as inadequate cleaning of the perfusion system. Once introduced in the perfusion system, LPS accumulated and created a memory effect. Oxidative but not acid-base depyrogenation effectively reduced LPS levels to concentrations that were in accordance with FDA guidelines (<0.5 EU/mL) for medical equipment redeemed appropriate for re-use.