Biosensing Chlorpyrifos in Environmental Water Samples by a Newly Developed Carbon Nanoparticle-Based Indirect Lateral Flow Assay

利用新开发的基于碳纳米粒子的间接侧向流动分析技术对环境水样中的毒死蜱进行生物传感

阅读:10

Abstract

Pesticides are used in agriculture to prevent pests. Chlorpyrifos (CHLP) is an insecticide with potentially detrimental effects on humans, bees, and the aquatic environment. Its effects have led to a total ban by the European Union (EU), but outside the EU, CHLP is still produced and used. An indirect lateral flow immunoassay (LFIA) for the detection of CHLP was developed and integrated into a cassette to create a lateral flow device (LFD). Species-specific reporter antibodies were coupled to carbon nanoparticles to create a detector conjugate. Water samples were mixed with a specific CHLP monoclonal antibody and detector conjugate and applied to the LFD. Dose-response curves elicited the detection of low concentrations of CHLP (<1 µg/L). This sensitivity was recorded through a rapid handheld digital imaging device but also visually by naked eye. The CHLP LFD was applied to a range of European surface water samples, fortified with CHLP, revealing a sensitivity in these matrices of 2 µg/L, both by digital and visual analysis. To improve the simplicity of the CHLP LFIA, the assay reagents were dried in tubes, enabling to carry out the test by simply adding water samples and inserting the LFIA strips. This CHLP LFIA is thus suited for the on-site screening of surface waters.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。