Combination of Filtered Bone Marrow Aspirate and Biomimetic Scaffold for the Treatment of Knee Osteochondral Lesions: Cellular and Early Clinical Results of a Single Centre Case Series

过滤骨髓抽吸物联合仿生支架治疗膝关节骨软骨损伤:单中心病例系列研究的细胞学和早期临床结果

阅读:2
作者:Matija Veber,Jan Vogler,Miomir Knežević,Ariana Barlič,Matej Drobnič

Abstract

Background: Osteochondral injury is a very common orthopaedic pathology, mainly affecting young, active population, with limited current treatment options. Herein we are presenting cellular and early clinical data of a patient series treated for chronic osteochondral lesions in the knee with a filter-based intra-operative bone marrow aspirate (BMA) separation device. Methods: Fifteen patients with chronic knee osteochondral lesions (60% females, 19-59 years) were included in this prospective case series. Filtered BMA (f-BMA), containing mesenchymal stem/stromal cells (MSCs), was combined with a biomimetic collagen-hydroxyapatite scaffold (CHAS) and implanted into the site of the lesion. Harvested BMA and post-separation f-BMA were analysed for blood cell counts, flow cytometry, and fibroblast colony forming units (CFU-Fs). Patients were followed for serious adverse events and graft failures. Clinical evaluation was assessed using the knee injury and osteoarthritis outcome score (KOOS). In 8 patients a magnetic resonance imaging (MRI)/arthroscopy were performed. Results: Cell suspension contained 0.027% CD271+ CD45- 7-AAD- cells, 0.15% CD73+ CD90+ CD105+ cells and 0.0012% CFU-Fs of all nucleated cells with 86% viability. Filtration process resulted in 12.8 (4.0-40.8) fold enrichment in terms of CFU-F content in comparison to initial BMA. No serious adverse events related directly to the osteochondral treatment were reported. After an average follow-up of 20 months (14-25) all KOOS subscales (Symptoms/Pain/Daily activities/Sport and recreation/Quality of life) increased significantly from pre-operative 55/56/67/30/30 to post-operative 73/76/79/51/52 (p values < 0.05), respectively. MRI or arthroscopic evaluation revealed nearly normal to normal overall International Cartilage Repair Society assessment in 7/8 patients. Conclusion: The filter-based BMA separation procedure significantly increased the frequency of mesenchymal stem/stromal cells (MSCs), however their concentration was not increased. The clinical evaluation revealed high safety profile of the treatment and resulted in improved clinical status of the patients.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。