Sensitive Serology Measurements in the Saliva of Individuals with COVID-19 Symptoms Using a Multiplexed Immunoassay

使用多重免疫测定法对出现 COVID-19 症状的人员唾液进行灵敏的血清学测量

阅读:2
作者:Dorsa Sohaei, Antigona Ulndreaj, Anu Mathew, Christopher Campbell, Martin Stengelin, George Sigal, Jessica Joe, Daniel Romero, Nikhil Padmanabhan, Annie Ren, Atefeh Ghorbani, Antoninus Soosaipillai, Vathany Kulasingam, Ioannis Prassas, Eleftherios P Diamandis

Background

There are numerous benefits to performing salivary serology measurements for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the causative pathogen for coronavirus disease 2019 (COVID-19). Here, we used a sensitive multiplex serology assay to quantitate salivary IgG against 4 SARS-CoV-2 antigens: nucleocapsid, receptor-binding domain, spike, and N-terminal domain.

Conclusions

This study shows that our multiplexed immunoassay can distinguish infected from uninfected individuals and reliably (93.3% specificity) detect seroconversion (in 60% of infected individuals) as early as the first week PSO, using easy-to-collect saliva samples.

Methods

We used single samples from 90 individuals with COVID-19 diagnosis collected at 0 to 42 days postsymptom onset (PSO) and from 15 uninfected control subjects. The infected individuals were segmented in 4 groups (0-7 days, 8-14 days, 15-21 days, and >21 days) based on days PSO, and values were compared to controls.

Results

Compared to controls, infected individuals showed higher levels of antibodies against all antigens starting from 8 days PSO. When applying cut-offs with at least 93.3% specificity at every time interval segment, nucleocapsid protein serology had the best sensitivity at 0 to 7 days PSO (60% sensitivity [35.75% to 80.18%], ROC area under the curve [AUC] = 0.73, P = 0.034). Receptor-binding domain serology had the best sensitivity at 8 to 14 days PSO (83.33% sensitivity [66.44%-92.66%], ROC AUC = 0.90, P < 0.0001), and all assays except for N-terminal domain had 92% sensitivity (75.03%-98.58%) at >14 days PSO. Conclusions: This study shows that our multiplexed immunoassay can distinguish infected from uninfected individuals and reliably (93.3% specificity) detect seroconversion (in 60% of infected individuals) as early as the first week PSO, using easy-to-collect saliva samples.