A multicenter study on the comparability of myocardial strain values acquired with different CMR scanners and analyzed with different post-processing software: insights into the "Traveling Volunteers" study

一项关于使用不同心脏磁共振扫描仪采集并使用不同后处理软件分析的心肌应变值可比性的多中心研究:来自“流动志愿者”研究的启示

阅读:2

Abstract

PURPOSE: Strain quantifies myocardial deformation. Despite its high diagnostic value, strain analyses using cardiovascular magnetic resonance (CMR) feature tracking (FT) have not been fully implemented into clinical routine due to lack of information on reproducibility. The purpose of this study was to assess the comparability of cardiovascular magnetic resonance CMR FT strain and ejection fraction (EF) measurements, obtained from different MR scanners and analyzed using different software platforms. METHODS: CMR examinations were performed in 15 healthy volunteers using three different scanners (German Heart Center of the Charité, Charité Campus Berlin Buch, and Theresien-Hospital Mannheim). FT was performed using Medis Suite and Circle CVI. Inter-software/scanner agreement was determined using Bland-Altman plots, Wilcoxon test, and paired Student's t test. Intra-/inter-observer reproducibility was evaluated using intraclass correlation coefficients. RESULTS: Left ventricular (LV) global longitudinal (GLS) and circumferential (GCS) strain did not differ between the three centers (small bias of - 1.27 to 1.32% for GLS and 0.91 to 0.69% for GCS). Inter-scanner agreement was lower regarding LV global radial strain (GRS) (bias of - 2.29 to 4.53%) and good for LV EF (bias of - 0.59 to 0.94%). Inter-software agreement was low for GLS (bias of - 5.72 to - 4.59%), GCS (- 1.13 to - 1.55%), and GRS (18.34 to 19.83%), with higher GLS/GCS and lower GRS values in CVI than Medis. LV EF showed better inter-software agreement (biases of - 0.07 to 0.06%). Intra- and inter-observer reproducibility was good for strain measurements across all scanners (bias of - 0.01 to 2.05 and 0.22 to 1.92, respectively) and software packages (ICC 0.70 to 0.90 and 0.51 to 0.89, respectively). CONCLUSION: Inter-scanner reproducibility for CMR FT measurements was high for GLS and GCS, suggesting potential use in routine CMR examinations. However, strain values between the two software vendors (CVI and Medis) were significantly different, indicating the need for standardization and implementation of software-specific cutoff values.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。