Cardiac Loading using Passive Left Atrial Pressurization and Passive Afterload for Graft Assessment

利用被动左心房加压和被动后负荷进行心脏负荷评估

阅读:2

Abstract

Ex vivo machine perfusion or normothermic machine perfusion is a preservation method that has gained great importance in the transplantation field. Despite the immense opportunity for assessment due to the beating state of the heart, current clinical practice depends on limited metabolic trends for graft evaluation. Hemodynamic measurements obtained from left ventricular loading have garnered significant attention within the field due to their potential as objective assessment parameters. In effect, this protocol provides an easy and effective manner of incorporating loading capabilities to established Langendorff perfusion systems through the simple addition of an extra reservoir. Furthermore, it demonstrates the feasibility of employing passive left atrial pressurization for loading, an approach that, to our knowledge, has not been previously demonstrated. This approach is complemented by a passive Windkessel base afterload, which acts as a compliance chamber to maximize myocardial perfusion during diastole. Lastly, it highlights the capability of capturing functional metrics during cardiac loading, including left ventricular pulse pressure, contractility, and relaxation, to uncover deficiencies in cardiac graft function after extended periods of preservation times (˃6 h).

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。