Multicentre comparison of various microaxial pump devices as a bridge to durable assist device implantation

多中心比较各种微型轴流泵装置作为持久辅助装置植入的过渡方案

阅读:2

Abstract

AIMS: Patients with acute decompensated advanced heart failure requiring left ventricular assist device (LVAD) implantation often experience progressive cardiac function deterioration, negatively impacting surgical outcomes. This study aimed to assess the efficacy of different microaxial flow pump (mAFP) support devices (Impella®) in achieving optimal left ventricular unloading for preconditioning and facilitating definitive treatment in this high-risk patient cohort. METHODS AND RESULTS: A retrospective analysis was conducted across 19 high-volume European centres. The study population included patients transitioning from temporary to durable circulatory support over a 7.5-year period, with a median follow-up of 1 year. Patients were categorized based on mAFP support capacity: those receiving high-flow support (>5 L/min, '5+') and those with lower-flow support (3.5 L/min, 'CP'). Patients who were initially treated with CP but subsequently upgraded to 5+ support were classified in the 5+ group. Demographic and clinical characteristics, mobilization, right heart function, and organ dysfunction outcomes were analysed. A total of 339 patients received preoperative mAFP support prior to LVAD implantation. The 5+ group comprised 247 patients (73%), including 38 patients who were upgraded from CP, while the CP group included 92 patients (27%). Baseline demographic and clinical characteristics were comparable between groups, except for mobilization status, which showed significant differences (P < 0.001). Patients in the 5+ group achieved higher rates of full and partial mobilization compared to the CP group. Extracorporeal life support (ECLS) was more frequently required in the CP group than in the 5+ group (40.5% vs. 33.8%; P < 0.001). Additionally, right ventricular assist device (RVAD) implantation was significantly more common in the CP group (29.2% vs. 18.2%; P = 0.026). Patients in the 5+ group demonstrated greater reductions in both vasoactive inotropic scores (P = 0.006) and inotropic scores (P = 0.008). Furthermore, liver dysfunction (P = 0.016), renal failure (P = 0.041), and the need for dialysis (P = 0.013) were significantly more prevalent in the CP group. There were no significant differences between the two groups in terms of LVAD operative duration (P = 0.637) or cardiopulmonary bypass time (P = 0.408). CONCLUSIONS: High-flow mAFP devices (+5) provided superior haemodynamic support, enhanced left ventricular unloading, and reduced dependence on catecholamines compared to lower-flow CP devices. These improvements were associated with lower rates of right ventricular failure, renal dysfunction, and liver injury. However, no statistically significant difference was observed between mAFP groups regarding 30-day mortality rates.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。