Efficacy and Safety of Percutaneous ASD Closure in Adults: Comparative Outcomes of Occluder Devices in a Single-Center Cohort

经皮房间隔缺损封堵术治疗成人患者的疗效和安全性:单中心队列中不同封堵器装置的比较结果

阅读:1

Abstract

Background: Atrial septal defect (ASD) is a prevalent congenital heart condition, resulting in left-to-right shunting. Untreated ASDs may be associated with complications, including right-sided heart failure, pulmonary hypertension, and atrial arrhythmias. Percutaneous ASD closure, performed with various occluder devices, has become the preferred approach for symptomatic patients with suitable anatomy, yet data on device-specific efficacy and safety profiles remain limited. Methods: This study was a retrospective, single-center analysis involving patients who underwent percutaneous ASD closure between January 2000 and February 2023. Data on patient characteristics, indications for the procedure, procedural details, and clinical outcomes were extracted from electronic medical records. Endpoints included complications at the puncture site, pericardial effusion, atrial arrhythmias, device-related thrombus formation, and overall survival. Results: A total of 195 patients were included (mean age 53.6 ± 16.2 years; 60.5% female). Three different devices were used: Amplatzer ASD occluder (n = 111), Gore Septal Occluder (n = 67), and Occlutech ASD occluder (n = 17). Initial procedural success rate was 90.8%, with no significant differences observed between devices. Periprocedural complication rates were low and comparable across all devices. New-onset atrial fibrillation within the first month post-implantation occurred in 7.5% of patients with the Gore device, compared to 0.9% with the Amplatzer device (p = 0.03) and 0% with the Occlutech device. No statistically significant differences were observed among the devices regarding thrombus formation, late-onset pericardial effusion, device erosion, or stroke. Conclusions: Percutaneous ASD closure demonstrates high procedural success and low complication rates across different occluder devices, supporting its efficacy and safety as a treatment for adults. Although the Gore device showed a higher incidence of new-onset AF compared to the Amplatzer device, no significant differences were observed regarding thrombus formation, pericardial effusion, device erosion or stroke.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。