High Detection Rates of Pancreatic Cancer Across Stages by Plasma Assay of Novel Methylated DNA Markers and CA19-9

通过血浆检测新型甲基化DNA标志物和CA19-9,可实现各期胰腺癌的高检出率

阅读:2

Abstract

PURPOSE: We have previously identified tissue methylated DNA markers (MDMs) associated with pancreatic ductal adenocarcinoma (PDAC). In this case-control study, we aimed to assess the diagnostic performance of plasma MDMs for PDAC. EXPERIMENTAL DESIGN: Thirteen MDMs (GRIN2D, CD1D, ZNF781, FER1L4, RYR2, CLEC11A, AK055957, LRRC4, GH05J042948, HOXA1, PRKCB, SHISA9, and NTRK3) were identified on the basis of selection criteria applied to results of prior tissue experiments and assays were optimized in plasma. Next, 340 plasma samples (170 PDAC cases and 170 controls) were assayed using target enrichment long-probe quantitative amplified signal method. Initially, 120 advanced-stage PDAC cases and 120 healthy controls were used to train a prediction algorithm at 97.5% specificity using random forest modeling. Subsequently, the locked algorithm derived from the training set was applied to an independent blinded test set of 50 early-stage PDAC cases and 50 controls. Finally, data from all 340 patients were combined, and cross-validated. RESULTS: The cross-validated area under the receiver operating characteristic curve (AUC) for the training set was 0.93 (0.89-0.96) for the MDM panel alone, 0.91 (95% confidence interval, 0.87-0.96) for carbohydrate antigen 19-9 (CA19-9) alone, and 0.99 (0.98-1) for the combined MDM-CA19-9 panel. In the test set of early-stage PDAC, the AUC for MDMs alone was 0.84 (0.76-0.92), CA19-9 alone was 0.87 (0.79-0.94), and combined MDM-CA19-9 panel was 0.90 (0.84-0.97) significantly better compared with either MDMs alone or CA19-9 alone (P = 0.0382 and 0.0490, respectively). At a preset specificity of 97.5%, the sensitivity for the combined panel in the test set was 80% (28%-99%) for stage I disease and 82% (68%-92%) for stage II disease. Using the combined datasets, the cross-validated AUC was 0.9 (0.86-0.94) for the MDM panel alone and 0.89 for CA19-9 alone (0.84-0.93) versus 0.97 (0.94-0.99) for the combined MDM-CA19-9 panel (P ≤ 0.0001). Overall, cross-validated sensitivity of MDM-CA19-9 panel was 92% (83%-98%), with an observed specificity of 92% at the preset specificity of 97.5%. CONCLUSIONS: Plasma MDMs in combination with CA19-9 detect PDAC with significantly higher accuracy compared with either biomarker individually.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。