Artificial intelligence versus manual screening for the detection of diabetic retinopathy: a comparative systematic review and meta-analysis

人工智能与人工筛查在糖尿病视网膜病变检测中的比较:一项系统评价和荟萃分析

阅读:2

Abstract

BACKGROUND: Diabetic retinopathy is one of the leading causes of blindness globally, among individuals with diabetes mellitus. Early detection through screening can help in preventing disease progression. In recent advancements artificial Intelligence assisted screening has emerged as an alternative to traditional manual screening methods. This diagnostic test accuracy (DTA) review aims to compare the sensitivity and specificity of AI versus manual screening for detecting diabetic retinopathy, focusing on both dilated and un-dilated eyes. METHODS: A systematic review and meta-analysis were conducted for comparison of AI vs. manual screening of diabetic retinopathy using 25 observational (cross sectional, validation and cohort) studies with total images of 613,690 used for screening published between January 2015 and December 2024. Outcomes of the study was sensitivity, and specificity. Risk of bias was assessed using the QUADAS-2 tool for validation studies, the AXIS tool for cross-sectional studies, and the Newcastle-Ottawa Scale for cohort studies. RESULTS: The results of this meta-analysis showed that for un-dilated eyes, AI screening showed pooled sensitivity of 0.90 [95% CI: 0.85-0.94] and pooled specificity of 0.94 [95% CI: 0.91-0.96] while manual screening shows pooled sensitivity of 0.79 [95% CI: 0.60-0.91] and pooled specificity of 0.99 [95% CI: 0.98-0.99]. For dilated eyes the pooled sensitivity of AI screening is 0.95 [95% CI: 0.91-0.97] and pooled specificity is 0.87 [95% CI: 0.79-0.92], while manual screening sensitivity is 0.90 [95% CI: 0.87-0.92] and specificity is 0.99 [95% CI: 0.99-1.00]. These data show comparable sensitivities and specificities of AI and manual screening, with AI performing better in sensitivity. CONCLUSION: AI-assisted screening for diabetic retinopathy shows comparable sensitivity and specificity compared to manual screening. These results suggest that AI can be a reliable alternative in clinical settings, with increased early detection rates and reducing the burden on ophthalmologists. Further research is needed to validate these findings. SYSTEMATIC REVIEW REGISTRATION: https://www.crd.york.ac.uk/PROSPERO/home, CRD42024596611.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。