Abstract
OBJECTIVE: The immunochromatographic rapid tests facilitate the early diagnosis of dengue by providing evidence of the presence of virus specific proteins (antigens/ antibody) in human blood. Many products for rapid dengue diagnosis are available in the market; the performance of few selected products was evaluated and compared with enzyme linked immuno sorbent assays (ELISA). METHODS: Sera from a large number of patients (n=184) admitted to National Institute of Blood Diseases & Bone Marrow Transplantation (NIBD) were used to determine the efficiency of non-structural (NS) 1, IgA, IgG and IgM based rapid test devices for dengue diagnosis. RESULTS: The dengue NS1 antigen based device was least efficient while among the antibody based devices the dengue IgA rapid test (RDT) was comparatively better (specificity: 80.95%; sensitivity: 85.21%). This device could detect both primary and secondary dengue infection and was found to be the most sensitive device at all point of sample collection. CONCLUSION: The dengue IgA RDT could be a cost effective and efficient rapid test device for timely dengue diagnosis at all levels of healthcare settings.