Using Electromagnetic Articulography to Measure Denture Micromovement during Chewing with and without Denture Adhesive

利用电磁关节描记法测量咀嚼过程中使用和不使用义齿粘合剂时义齿的微动

阅读:1

Abstract

PURPOSE: To study the effects of denture adhesive upon denture micromovements in three dimensions during the chewing of hard, sticky, and tough food items observed using a novel method involving an electromagnetic articulograph (EMA) speech research system. MATERIALS AND METHODS: Ten volunteers (mean age 60.9 ± 10.4 years) with fair- or poor-fitting complete maxillary dentures were enrolled. Chewing experiments were conducted using two treatments (adhesive or no-adhesive control) and three foods: carrots (hard), raisins (sticky), and processed meat stick (tough). Denture micromovement was measured through a novel application of a Northern Digital Wave EMA System. Three-dimensional denture position was captured during mastication using three sensors embedded into a replica denture for each subject. Following individual characterization of a "home" reference position, the Euclidean Distances from Home (DfH) were calculated for each recorded sample of the chewing experiments. The DfH at each sample represented the denture movement for that 1/100th of a second of the activity. The DfH data were then summarized as the mean DfH, the maximum DfH, and total distance traveled by the denture. Several thresholds were also analyzed, including the percent of time that the DfH ≥1.5 mm, ≥2.0 mm, and ≥2.5 mm. RESULTS: With adhesive treatment, the mean DfH of dentures during chewing was reduced by 26.8% for carrot, 30.3% for raisin, and 31.0% for meat stick, when compared with no-adhesive treatment (p < 0.001 for all comparisons). Similar results were also seen for the maximum DfH and total distance travelled endpoints across foods. For the threshold endpoints, adhesive treatment was associated with a statistically significant reduction in denture micromovements at all three thresholds across foods. At the threshold of DfH ≥ 1.5 mm, adhesive treatment was associated with a reduction in micromovement by 61.6%, 56.2%, and 70.0% with carrot, raisin, and meat stick, respectively (p ≤ 0.004 for all comparisons). CONCLUSIONS: Observations of denture movement using the Wave EMA System were able to differentiate systematically between adhesive treatment and no-adhesive treatment for denture micromovements during different chewing challenges. Use of adhesive was associated with statistically significant reductions in denture micromovements for hard, sticky, and tough foods as measured with both distance and threshold endpoints.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。