[Determination of vitamin D and 25-hydroxyvitamin D in animal-derived foods by derivatization-ultra performance liquid chromatography-tandem mass spectrometry]

[衍生化-超高效液相色谱-串联质谱法测定动物源性食品中的维生素D和25-羟基维生素D]

阅读:2

Abstract

Animal-derived foods are essential sources of vitamin D and 25-hydroxyvitamin D in the human diet. Currently, the relevant regulatory methods in China are limited to using non-derivatization methods to determine vitamin D content. In this study, 4-phenyl-1,2,4-triazoline-3-5-dione (PTAD) was used as a derivative reagent, and the ionization efficiencies of vitamin D and 25-hydroxyvitamin D were improved by introducing readily ionizable groups via the Diels-Alder reaction. This method allowed for the simultaneous determination of vitamin D and 25-hydroxyvitamin D in animal-derived foods using derivatization and ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The conditions for derivatization, sample pretreatment, chromatographic separation, and MS detection were optimized. The results showed that the derivatization reaction was effective in acetonitrile solvent at a target compound to PTAD mass ratio of 1∶10000 and stabilized after 1 h. Compared with Silica and C(18) solid-phase extraction (SPE) columns, hydrophilic lipophilic balanced (HLB) SPE columns yielded higher recoveries of the target compounds, while simultaneously reducing the matrix effect. The detection sensitivity was significantly improved by adding 5 mmol/L methylamine to the water-methanol mobile phase system. An isotopic internal standard was added to the homogenized samples, which were saponified with alkali solution, extracted and concentrated, purified using a SPE column, derivatized, and separated on a Waters Acquity UPLC BEH C(18) column (100 mm×2.1 mm, 1.7 μm) with a gradient elution using 0.1% formic acid-5 mmol/L methylamine aqueous solution and 0.1% formic acid-5 mmol/L methylamine of methanol as the mobile phases. The analytes were determined by multiple reaction monitoring (MRM) in positive electrospray ionization mode (ESI(+)) and quantified using the internal standard method. The results for both vitamin D and 25-hydroxyvitamin D showed good linearity in the range of 0.2-50 μg/L, with correlation coefficients of 0.9995-0.9999. The limits of detection (LODs) and limits of quantification (LOQs) were in the range of 0.018-0.066 and 0.06-0.22 μg/kg, respectively. Recoveries were 92.6%-99.4% at three spiked levels (0.20, 1.0, and 5.0 μg/kg), and the relative standard deviations (RSDs) were 3.6%-6.2%. This highly sensitive method yields reproducible and accurate results for the quantitative determination of vitamin D and 25-hydroxyvitamin D in animal-derived foods.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。