Quantitating the concentration of Py-Im polyamide-fluorescein conjugates in live cells

定量分析活细胞中 Py-Im 聚酰胺-荧光素缀合物的浓度

阅读:2

Abstract

Quantitative fluorescence-based methods have been developed to determine the nuclear concentration of polyamide-fluorescein conjugates in cell culture. Confocal laser scanning microscopy and flow cytometry techniques are utilized to plot calibration curves, from which the nuclear concentration can be interpolated. Upon treatment with polyamide, the concentration in the nucleus of live HeLa cells is calculated to be between 0.1 and 0.5microM, which is significantly lower than the 2microM dosage concentration. In contrast, the observed nuclear concentration in U251 cells is closer to the dosage concentration, indicating a cell line-specific increase in uptake for this class of compounds. Although confocal microscopy and flow cytometry generate disparate values, taken together these experiments suggest that the polyamide concentration inside the cell nucleus is lower than it is outside the cell.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。