Associations of Fully Automated CSF and Novel Plasma Biomarkers With Alzheimer Disease Neuropathology at Autopsy

全自动脑脊液和新型血浆生物标志物与阿尔茨海默病尸检神经病理学的关联

阅读:2

Abstract

OBJECTIVE: To study CSF biomarkers of Alzheimer disease (AD) analyzed by fully automated Elecsys immunoassays compared to neuropathologic gold standards and to compare their accuracy to plasma phosphorylated tau (p-tau181) measured with a novel single molecule array method. METHODS: We studied antemortem Elecsys-derived CSF biomarkers in 45 individuals who underwent standardized postmortem assessments of AD and non-AD neuropathologic changes at autopsy. In a subset of 26 participants, we also analyzed antemortem levels of plasma p-tau181 and neurofilament light (NfL). Reference biomarker values were obtained from 146 amyloid-PET-negative healthy controls (HC). RESULTS: All CSF biomarkers clearly distinguished pathology-confirmed AD dementia (n = 27) from HC (area under the curve [AUC] 0.86-1.00). CSF total tau (t-tau), p-tau181, and their ratios with β-amyloid(1-42) (Aβ(1-42)) also accurately distinguished pathology-confirmed AD from non-AD dementia (n = 8; AUC 0.94-0.97). In pathology-specific analyses, intermediate to high Thal amyloid phases were best detected by CSF Aβ(1-42) (AUC [95% confidence interval] 0.91 [0.81-1]), while intermediate to high scores for Consortium to Establish a Registry for Alzheimer's Disease neuritic plaques and Braak tau stages were best detected by CSF p-tau181 (AUC 0.89 [0.79-0.99] and 0.88 [0.77-0.99], respectively). Optimal Elecsys biomarker cutoffs were derived at 1,097, 229, and 19 pg/mL for Aβ(1-42), t-tau, and p-tau181. In the plasma subsample, both plasma p-tau181 (AUC 0.91 [0.86-0.96]) and NfL (AUC 0.93 [0.87-0.99]) accurately distinguished those with pathology-confirmed AD (n = 14) from HC. However, only p-tau181 distinguished AD from non-AD dementia cases (n = 4; AUC 0.96 [0.88-1.00]) and showed a similar, although weaker, pathologic specificity for neuritic plaques (AUC 0.75 [0.52-0.98]) and Braak stage (AUC 0.71 [0.44-0.98]) as CSF p-tau181. CONCLUSION: Elecsys-derived CSF biomarkers detect AD neuropathologic changes with very high discriminative accuracy in vivo. Preliminary findings support the use of plasma p-tau181 as an easily accessible and scalable biomarker of AD pathology. CLASSIFICATION OF EVIDENCE: This study provides Class II evidence that fully automated CSF t-tau and p-tau181 measurements discriminate between autopsy-confirmed AD and other dementias.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。