A testing time for gradient strips: an evaluation of ETEST for the antimicrobial susceptibility testing of Neisseria gonorrhoeae

梯度试纸条的测试时间:ETEST 在淋病奈瑟菌抗菌药物敏感性测试中的应用评价

阅读:4

Abstract

Introduction. Antimicrobial susceptibility testing (AST) of Neisseria gonorrhoeae isolates is recommended in the UK to ensure antimicrobial stewardship and detection of multi-drug and extensively resistant cases. In diagnostic and reference laboratories, this testing is primarily carried out via a gradient strip. However, agar dilution methodology may also be used for high-throughput testing.Gap statement. N. gonorrhoeae is not a validated species on all ETEST (bioMérieux, France) gradient strip formulations available, and, therefore, additional comparative validation data are required to support use in clinical laboratory settings.Aim. To determine the reproducibility of ETEST for AST of N. gonorrhoeae, and to demonstrate the comparability of susceptibility results obtained using agar dilution and gradient strip methods.Methodology. Modal ETEST MICs for six well-characterized World Health Organization N. gonorrhoeae control strains, against eight antimicrobials, were calculated. ETEST modal MICs were compared to published and local, historical agar dilution MICs. MICs were interpreted using European Committee on Antimicrobial Susceptibility Testing (EUCAST) breakpoints. Concordance of ETEST modal MICs, within essential and categorical agreement, for each strain was calculated.Results. Overall, 95.80% of modal ETEST MICs were within essential agreement with published MICs. Where variance from exact concordance was noted, a systematic shift was observed to lower MICs in this study. On three occasions, variance from the published MIC resulted in a categorical classification change. On two occasions, the modal ETEST MIC in this study was two doubling dilutions lower than the published MIC. Neither resulted in a categorical classification change. When modal ETEST and agar dilution MICs were compared, overall essential agreement was 83.30%. However, this increased to 94.4% when concordance was analysed for clinically important antimicrobials: azithromycin, cefixime and ceftriaxone. Again, a systematic shift to lower MICs for ETEST was observed in this study. Categorical agreement was 83.3% for all antimicrobials and 100% for clinically important antimicrobials.Conclusion. Excellent concordance was demonstrated for MICs generated using ETEST with published MICs. Good concordance was observed for MICs generated using two different susceptibility testing methodologies. Where variance was noted, MICs generally read lower on ETEST in this study. ETEST remains fit for purpose for the AST of N. gonorrhoeae, a clinically important pathogen.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。