Heterogeneity of false reactivity profiles of HIV assays while optimizing national HIV testing algorithms: Findings from a multi-country analysis

在优化国家艾滋病毒检测流程的过程中,艾滋病毒检测假阳性反应谱的异质性:一项多国分析的研究结果

阅读:2

Abstract

This study highlights the importance of verifying HIV testing algorithms to reduce the risk of misdiagnoses caused by common false reactivity. Between 2020 and 2023, WHO supported 14 countries to assess rates of false reactivity and shared false reactivity across HIV rapid diagnostic tests (RDTs) used in HIV testing services. The study involved 26,278 results from 22 different RDT products, with sample sizes ranging from 100 to 302 results per country. The number of RDT products assessed varied between 4 and 13 per country. False reactivity rates ranged from 0 % to 3.32 %, with one country reporting a high false reactivity rate of over 4 % for one RDT. Five countries have no shared false reactivity between RDTs, while the remaining eight countries shared false reactivity across one to six pairs of RDT products. These findings were used to inform national policy, with more than 90 % of countries introducing new RDT products into their HIV testing algorithm based on these results. The study concludes that rates of false reactivity and shared false reactivity between RDT products vary across countries. Therefore, conducting verification studies is crucial for updating national HIV testing algorithms and ensuring accurate diagnosis while also facilitating the market entry of new HIV testing products.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。