First-Trimester Morphological Evaluation of Fetuses and Medical Law Implications

妊娠早期胎儿形态学评估及其在医疗法律中的意义

阅读:3

Abstract

Background/Objectives: Over the years, the potential of the first-trimester (FT) ultrasound in the detection of fetal structural defects has increased. The main objectives of the first-trimester fetal screening evaluation are the detection of major structural anomalies and the diagnosis of additional sonographic markers for chromosomal disorders. When a fetal anomaly is diagnosed, patients have the right to be informed about the risks, necessary interventions, or alternatives. Depending on the severity of the anomalies and the pregnancy period, the legality of the pregnancy termination was evaluated. The aim of this study was to assess the impact of the first-trimester morphological screening of the fetus using an ultrasound protocol according to the latest international protocols (the ISUOG protocol). Methods: Between 1 January 2024 and 31 December 2024, 854 pregnancies with gestational ages between 11 weeks and 13 weeks + 6 days were morphologically evaluated during the nuchal scan in the Obstetrics and Gynecology Department of the Emergency County Hospital from Craiova. Both transabdominal and transvaginal ultrasound in 2D and in a color Doppler mode were used in the scanning technique. The ultrasound findings were correlated with the genetic testing results and pregnancy outcome. The medical law implications were related to the cases where the ultrasound was performed at about 13 weeks of gestation, and the screening genetic results showed an increased pregnancy risk, which arose during the FT. In these cases, we performed amniocentesis at about 16-17 weeks of gestation, and especially, the Non-Invasive Prenatal Testing (NIPT)-positive cases were confirmed by karyotyping. Still, at this gestational age of diagnosis, the Romanian law would not allow abortions. Results: By using this extended FT ultrasound protocol, we detected 58 cases with fetal structural anomalies. Eighteen cases were also associated with genetic syndromes after performing chorionic villous sampling (CVS). Three cases detected with minor structural anomalies (two cases with club foot and one case with a cleft upper lip) were lost to follow-up. Conclusions: Fetal morphological ultrasound evaluation is feasible in the late first trimester. By using an extended ultrasound protocol, we can detect most of the fetal structural anomalies and contribute to better medical counseling and improve pregnancy outcomes.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。