A Combination of Artificial Intelligence with Genetic Algorithms on Static Time-Lapse Images Improves Consistency in Blastocyst Assessment, An Interpretable Tool to Automate Human Embryo Evaluation: A Retrospective Cohort Study

人工智能与遗传算法相结合处理静态延时图像可提高囊胚评估的一致性,为人类胚胎评估自动化提供可解释的工具:一项回顾性队列研究

阅读:1

Abstract

BACKGROUND: In recent times, various algorithms have been developed to assist in the selection of embryos for transfer based on artificial intelligence (AI). Nevertheless, the majority of AI models employed in this context were characterized by a lack of transparency. To address these concerns, we aim to design an interpretable tool to automate human embryo evaluation by combining artificial neural networks (ANNs) and genetic algorithms (GA). MATERIALS AND METHODS: This retrospective cohort study included 223 human blastocyst time-lapse (TL) images taken at 110 hours post-injection. All the images were evaluated by five embryologists from different clinics in terms of blastocyst expansion (BE), quality of the inner cell mass (ICM), and trophectoderm (TE). The embryo database was used to develop an AI system (70% training, 15% validation, and 15% test) for automate blastocyst assessment. The entire set of images underwent a standardization process, followed by processing and segmentation using Matlab software. The resulting quantified variables were utilized in AI techniques (ANN and GA). Finally, the accuracy and performance of the automation tool was assessed with the area under the receiver operating characteristic (ROC) curve (AUC). Then, the level of agreement among embryologists and between embryologists and the AI system was compared with Kappa Index. RESULTS: The overall agreement among embryologists was low (Kappa: 0.4 for BE; and 0.3 for TE and ICM). The AI tool achieved higher consistency (Kappa 0.7 for BE and ICM; and 0.4 for TE). The AI exhibited high accuracy in classifying BE (test 81.5%), ICM (test 78.8%), and TE (test 78.3%) and better performance for BE (AUC 0.888-0.956) than for ICM (AUC 0.605-0.854) and TE (AUC 0.726-0.769) assessment. CONCLUSION: Our AI tool highlighted the superior consistency of AI compared to human operators in grading blastocyst morphology. This research represents an important step towards fully automating objective embryo evaluation.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。