Left ventricular systolic function in subjects conceived through assisted reproductive technologies

通过辅助生殖技术受孕的受试者的左心室收缩功能

阅读:1

Abstract

BACKGROUND: Over the past decades, assisted reproductive technologies (ART) have gained remarkable influence in the treatment of infertility and account for more than 2 % of births in European countries nowadays. Accumulating evidence suggests ART to cause cardiovascular alterations, including left ventricular (LV) dysfunctions, within its offspring. The aim of this study was to assess LV systolic function in subjects conceived through ART in comparison to spontaneously conceived peers. METHODS: For the assessment of LV morphology and LV function, M-Mode echocardiography, pulsed wave Doppler and two-dimensional speckle tracking echocardiography (2DSTE) were applied. LV ejection fraction (EF) and fractional shortening (FS) were assessed in M-Mode and calculated by Teichholz formula. EF was additionally assessed semiautomatically through 2DSTE. RESULTS: In total, 64 ART subjects and 83 spontaneously conceived controls with no significant differences in age (12.52 ± 5.64 years vs. 13.20 ± 5.95 years, p = 0.486) and sex were included in the analysis. In the ART cohort, significantly lower values were observed for M-Mode assessed EF (63.63 ± 5.17 % vs. 65.35 ± 5.10 %, p = 0.046) and FS (34.26 ± 3.87 % vs. 35.60 ± 3.84 %, p = 0.038). However, after the adjustment for birth weight percentile and gestational age, M-Mode assessed EF and FS displayed no significant differences between both groups. LV morphology and remaining systolic function parameters, such as mitral annular plane systolic excursion, aortic velocity time integral, global peak longitudinal strain and 2DSTE measured EF, were comparable between both groups. CONCLUSION: This study suggests a lower LV systolic function in ART subjects, visualized by significantly lower values for M-Mode assessed EF and FS, compared to spontaneously conceived peers. The clinical relevance of these findings has to be investigated as the above-mentioned parameters were in normal reference range. In addition, LV systolic function parameters evaluated by other echocardiographic imaging modalities were comparable between both groups. Therefore, further studies will be required to evaluate the influence of ART on LV systolic function and cardiovascular morbidity in the future.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。