Aerosol Box Use in Reducing Health Care Worker Contamination During Airway Procedures (AIRWAY Study): A Simulation-Based Randomized Clinical Trial

使用气溶胶箱减少医护人员在气道操作过程中的污染(AIRWAY 研究):一项基于模拟的随机临床试验

阅读:1

Abstract

IMPORTANCE: The aerosol box has been used during the management of patients with COVID-19 to reduce health care practitioner (HCP) exposure during aerosol-generating medical procedures (AGMPs). Little is known about the effect of aerosol box use on HCP contamination and AGMP procedure time. OBJECTIVE: To investigate whether use of an aerosol box during AGMPs reduces HCP contamination or influences the time to successful completion and first-pass success rate for endotracheal intubation (ETI) and laryngeal mask airway (LMA) insertion. DESIGN, SETTING, AND PARTICIPANTS: This multicenter, simulation-based, randomized clinical trial was conducted from May to December 2021 at tertiary care pediatric hospitals. Participant teams performed 3 simulated patient scenarios: bag-valve-mask ventilation, ETI, and LMA insertion. During the scenarios, aerosols were generated using Glo Germ. Teams of 2 HCPs were randomly assigned to control (no aerosol box) or intervention groups (aerosol box). Statistical analysis was performed from July 2022 to February 2023. INTERVENTIONS: The aerosol box (or SplashGuard CG) is a transparent, plastic barrier covering the patient's head and shoulders with access ports allowing HCPs to manage the airway. MAIN OUTCOMES AND MEASURES: The primary outcome was surface area of contamination (AOC) on participants. Secondary outcomes were time to successful completion and first-pass success rates for ETI and LMA insertion. RESULTS: A total of 64 teams (128 participants) were enrolled, with data from 61 teams (122 participants) analyzed. Among the 122 participants analyzed, 79 (64.8%) were female and 85 (69.7%) were physicians. Use of an aerosol box was associated with a 77.5% overall decreased AOC to the torso (95% CI, -86.3% to -62.9%; P < .001) and a 60.7% overall decreased AOC to the facial area (95% CI, -75.2% to -37.8%; P < .001) in airway HCPs. There was no statistically significant difference in surface contamination after doffing personal protective equipment between groups. Time to completing ETI was longer in the aerosol box group compared with the control group (mean difference: 10.2 seconds; 95% CI, 0.2 to 20.2 seconds; P = .04), but there was no difference between groups for LMA insertion (mean difference: 2.4 seconds; 95% CI, -8.7 to 13.5 seconds; P = .67). CONCLUSIONS AND RELEVANCE: In this randomized clinical trial of aerosol box use in AGMPs, use of an aerosol box reduced contamination deposition on HCPs' torso and face predoffing; the use of an aerosol box delayed time to successful intubation. These results suggest that the incremental benefits of reduced surface contamination from aerosol box use should be weighed against delayed time to complete intubation, which may negatively affect patient outcome. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT04880668.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。