A machine learning framework for classifying lipids in untargeted metabolomics using mass-to-charge ratios and retention times

一种利用质荷比和保留时间对非靶向代谢组学中的脂质进行分类的机器学习框架

阅读:3

Abstract

INTRODUCTION: The identification of unknown metabolites remains a major challenge in untargeted metabolomics using liquid chromatography-mass spectrometry (LC-MS). This process typically depends on comparing mass spectral or chromatographic data to reference databases or deciphering complex fragmentation in tandem mass spectra. While current machine learning methods can predict metabolite structures using MS/MS (MS2) data, no approaches, to our knowledge, use only mass-to-charge ratio (m/z) and retention time (RT) from LC-MS data. OBJECTIVE: To explore the potential of using the mass-to-charge ratio (m/z) and retention time (RT) from LC-MS data as standalone predictors for metabolite classification and propose a modeling framework which can be implemented internally on standalone datasets. METHODS: We trained machine learning models on 20 mouse lung adenocarcinoma tumor samples with 7,353 features and validated them on a dataset of 81 samples with 22,000 features. A total of 120 combination of preprocessors and models were assessed. Features were classified as "lipid" or "non-lipid" based on the Human Metabolome Database (HMDB) taxonomy, and model performance was assessed using accuracy, area under the receiver operating characteristic curve (AUC), and area under the precision-recall curve (PR). We replicate the process in an independent dataset generated using human plasma samples. RESULTS: We classified untargeted LC-MS features as "lipid" or "non-lipid" per the HMDB super class taxonomy and evaluated model performance. A framework including steps to choose the preprocessors and models for metabolite classification was designed. In our lab, tree-based models demonstrated superior performance across all metrics, achieving high accuracy, AUC, and PR which was consistent with the independent dataset. CONCLUSION: Our results demonstrate that metabolites can be classified as "lipid", "non-lipid" using only m/z and RT from untargeted LC-MS data, without requiring MS2 spectra. Although this study focused on lipid classification, the approach shows potential for broader application, which warrants further investigation across diverse compound classes, detection methods, and chromatographic conditions.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。