Simplification of dosimetry in (90)Y-radioembolization therapy by dual planar images

利用双平面图像简化 (90)Y 放射性栓塞治疗的剂量测定

阅读:5

Abstract

AIM: The purpose was to provide a practical and effective method for performing reliable (90)Y dosimetry based on (99m)Tc-MAA and SPEC/CT. The impact of scatter correction (SC) and attenuation correction (AC) on the injected (90)Y activity, lung shunt fraction (LSF) and the delivered dose to lung and liver compartments was investigated within the scope of the study. MATERIAL AND METHODS: Eighteen eligible patients (F: 3, M: 15) were subjected to (90)Y therapy. (99m)Tc-MAA (111-222 MBq) was injected into the targeted liver, followed by whole-body scan (WBS) with peak-window at 140 keV (15% width) and one down-scatter window. SPECT/CT scan was subsequently acquired encompassing lung and liver regions. The LSFs were fashioned from standard WBS LSFwb (St), scatter corrected WBS LSFwb (Sc), only scatter corrected SPECT LSFspect (NoAC-SC) and SPECT/CT with attenuation and scatter correction LSFspect (AC-SC). The absorbed doses that would be delivered to tumor and injected healthy liver were estimated using different calculation modes involving AC-SC (SPECT/CT), NoAC-SC (SPECT), NoAC-NoSC+LSFwb (SC), AC-SC + LSFwb (St), and NoAC-NoSC+LSFwb (St). RESULTS: The average deviations (range) in LSF values between standard LSFwb (St) and those from SPECT/CT (AC-SC), SPECT (NoAC-SC), and LSFwb (SC) were - 50% (- 29/- 71), - 32% (- 8/- 67), and - 45% (- 13/80), respectively. The suggested (90)Y activity (GBq/Gy) was decreased within a range of 2-11%, 1-9%, and 2-7% by using LSFspect (AC-SC), LSFspect (NoAC-SC), and LSFwb (SC), respectively. Overall, two-sample t-test yielded no statistically significant difference (p < 0.05) in the absorbed doses to tumor and injected healthy liver between AC-SC (SPECT) and the rest of approaches with/and without AC and SC. However, a statistically significant difference (p < 0.05) was demonstrated in the lung shunt fractions and lung doses due to AC and SC. The LSFs from scatter corrected planar images LSFwb (SC) exhibited well agreement (R(2) = 0.92) with SPECT/CT (AC-SC) and there was no statistically significant difference (P(value) > 0.05) between both methods. CONCLUSION: It was deduced that SPECT/CT with attenuation and scatter correction plays a crucial role in the measurements of lung shunt fraction and dose as well as the total number of (90)Y treatments. However, the absorbed dose to tumors and injected healthy liver was minimally affected by AC and SC. Besides, a good agreement was observed between LSF datasets from SPECT/CT versus scatter corrected WBS that can be alternatively and effectively used in (90)Y dosimetry.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。