Incidental irradiation of the regional lymph nodes during deep inspiration breath-hold radiation therapy in left-sided breast cancer patients: a dosimetric analysis

左侧乳腺癌患者深吸气屏气放射治疗期间区域淋巴结意外受照:剂量学分析

阅读:2

Abstract

BACKGROUND: Radiotherapy using the deep inspiration breath-hold (DIBH) technique compared with free breathing (FB) can achieve substantial reduction of heart and lung doses in left-sided breast cancer cases. The anatomical organ movement in deep inspiration also cause unintended exposure of locoregional lymph nodes to the irradiation field. METHODS: From 2017-2020, 148 patients with left-sided breast cancer underwent breast conserving surgery (BCS) or mastectomy (ME) with axillary lymph node staging, followed by adjuvant irradiation in DIBH technique. Neoadjuvant or adjuvant systemic therapy was administered depending on hormone receptor and HER2-status. CT scans in FB and DIBH position with individual coaching and determination of the breathing amplitude during the radiation planning CT were performed for all patients. Intrafractional 3D position monitoring of the patient surface in deep inspiration and gating was performed using Sentinel and Catalyst HD 3D surface scanning systems (C-RAD, Catalyst, C-RAD AB, Uppsala, Sweden). Three-dimensional treatment planning was performed using standard tangential treatment portals (6 or 18 MV). The delineation of ipsilateral locoregional lymph nodes was done on the FB and the DIBH CT-scan according to the RTOG recommendations. RESULTS: The mean doses (D(mean)) in axillary lymph node (AL) level I, II and III in DIBH were 32.28 Gy (range 2.87-51.7), 20.1 Gy (range 0.44-53.84) and 3.84 Gy (range 0.25-39.23) vs. 34.93 Gy (range 10.52-50.40), 16.40 Gy (range 0.38-52.40) and 3.06 Gy (range 0.21-40.48) in FB (p < 0.0001). Accordingly, in DIBH the D(mean) for AL level I were reduced by 7.59%, whereas for AL level II and III increased by 22.56% and 25.49%, respectively. The D(mean) for the supraclavicular lymph nodes (SC) in DIBH was 0.82 Gy (range 0.23-4.11), as compared to 0.84 Gy (range 0.22-10.80) with FB (p = 0.002). This results in a mean dose reduction of 2.38% in DIBH. The D(mean) for internal mammary lymph nodes (IM) was 12.77 Gy (range 1.45-39.09) in DIBH vs. 11.17 Gy (range 1.34-44.24) in FB (p = 0.005). This yields a mean dose increase of 14.32% in DIBH. CONCLUSIONS: The DIBH technique may result in changes in the incidental dose exposure of regional lymph node areas.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。