Direct estimation of activity concentration in regional voxels with application to (177)Lu peptide receptor radionuclide therapy

直接估算区域体素内的放射性浓度及其在(177)Lu肽受体放射性核素治疗中的应用

阅读:1

Abstract

BACKGROUND: Quantitative SPECT in radionuclide-therapy is limited by partial-volume effects (PVEs). The implementation of regional voxels (r.v.), estimating mean activity concentrations in regions directly from projections, offers a promising alternative for the geometry-specification to reduce PVEs. PURPOSE: This study aims to demonstrate that activity-concentration estimation with r.v. is superior to reconstruction with cuboid voxels (cu.v.) with post-reconstruction partial-volume correction (PVC) for estimation of activity concentration in (177)Lu peptide receptor radionuclide therapy ((177)Lu-PRRT). METHODS: Data originated from one patient administered [(177)Lu]Lu-DOTA-TOC with SPECT acquired at 1 d, 4 d and 7 d p.i. stored in list-mode format (dataset PA), and eight patients given [(177)Lu]Lu-DOTA-TATE with SPECT acquired 1 d p.i. (dataset PB). Activity concentration was estimated from reconstruction with cu.v. and using r.v. for both datasets, with multiple noise realizations for PA using bootstrapping. Organ delineation was performed based on CT using the AI tool TotalSegmentator, and tumor delineation made in cu.v. SPECT images. The estimated activity concentration for kidneys, spleen, and tumors from r.v. was compared to that obtained with cu.v. with and without post-reconstruction PVC. To study the accuracy of activity-concentration estimates, simulations were performed with the SIMIND Monte Carlo program with patient images used as basis. The sensitivity to misalignments between SPECT and CT was also evaluated. RESULTS: For both patient and simulated data, activity concentrations estimated with r.v. are higher than those from cu.v., with comparable standard deviations. Mean relative errors for simulated images from PA relative to simulation input at 1 d p.i. reconstructions with r.v. are (-4.6 ± 1.4) %, (3.0 ± 0.5) %, (0.1 ± 0.5) %, and (5.6 ± 1.2) % for tumor, left kidney, right kidney, and spleen, respectively. Corresponding results for cu.v. with post-reconstruction PVC are (-12.3 ± 2.2) %, (-4.2 ± 0.6) %, (-7.0 ± 0.5) %, and (-2.1 ± 1.1) %. For simulated images based on PB, the mean relative errors obtained for r.v. are (-3.1 ± 3.5) %, (1.2 ± 1.2) %, (-1.7 ± 1.1) %, and (2.3 ± 0.8) %, while for cu.v. with PVC they are (-7.9 ± 6.7) %, (-5.8 ± 1.9) %, (-9.0 ± 1.0) %, and (-0.7 ± 2.6) %. CONCLUSIONS: Regional voxels are superior to cu.v. for estimation of the activity concentration in organs in (177)Lu-PRRT and demonstrates lower sensitivity to misregistration errors. For tumors, r.v. yields lower systematic errors than cu.v. but demonstrates a higher sensitivity to image segmentation errors for volumes below approximately 10 mL.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。