Urine stabilization and normalization strategies favor unbiased analysis of urinary EV content

尿液稳定和标准化策略有利于对尿液 EV 含量进行无偏分析

阅读:15

Abstract

Urine features an ideal source of non-invasive diagnostic markers. Some intrinsic and methodological issues still pose barriers to its full potential as liquid biopsy substrate. Unlike blood, urine concentration varies with nutrition, hydration and environmental factors. Urine is enriched with EVs from urinary-genital tract, while its conservation, purification and normalization can introduce bias in analysis of EV subsets in inter-and intra-individual comparisons. The present study evaluated the methods that decrease such biases such as appropriate and feasible urine storage, optimal single-step EV purification method for recovery of proteins and RNAs from small urine volumes and a normalization method for quantitative analysis of urine EV RNAs. Ultracentrifugation, chemical precipitation and immuno-affinity were used to isolate EVs from healthy donors' urine that was stored frozen or at room temperature for up to 6 months. Multiple urine biochemical and EV parameters, including particle count and protein content, were compared across urine samples. To this purpose nanoparticle tracking analysis (NTA) and protein assessment by BCA, ELISA and WB assays were performed. These measurements were correlated with relative abundances of selected EV mRNAs and miRNAs assessed by RT-PCR and ranked for the ability to reflect and correct for EV content variations in longitudinal urine samples. All purification methods enabled recovery and downstream analysis of EVs from as few as 1 ml of urine. Our findings highlight long term stability of EV RNAs upon urine storage at RT as well as excellent correlation of EV content in urine with some routinely measured biochemical features, such as total urine protein and albumin, but not creatinine most conventionally used for urine normalization. Comparative evaluation of mRNA and miRNAs in EV isolates revealed specific RNAs, in particular RNY4 and small miRNA panel, levels of which well reflected the inter-sample EV variation and therefore useful as possible post-analytical normalizers of EV RNA content. We describe some realistic urine processing and normalization solutions for unbiased readout of EV biomarker studies and routine clinical sampling and diagnostics providing the input for design of larger validation studies employing urine EVs as biomarkers for particular conditions and diseases.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。