Hinged external fixation for Regan-Morrey type I and II fractures and fracture-dislocations

用于治疗 Regan-Morrey I 型和 II 型骨折及骨折脱位的铰链式外固定器

阅读:1

Abstract

Elbow fracture-dislocation is always demanding to manage due to the considerable soft-tissue swelling or damage involved, which can make an early open approach and ligamentous reconstruction impossible. The purpose of this study was to evaluate the role of elbow hinged external fixation (HEF) as a definitive treatment in patients with elbow dislocations associated with Regan-Morrey (R-M) type I and II coronoid fractures and soft-tissue damage. We treated 11 patients between 2010 and 2012 with HEF. Instability tests and standard X-ray examinations were performed before surgery and 1-3 to 3-6 months after surgery, respectively. All patients underwent a preoperative CT scan. Outcomes were assessed with a functional assessment scale (Mayo Elbow Performance Score, MEPS) that included 4 parameters: pain, ROM, stability, and function. The results were good or excellent in all 11 patients, and no patient complained of residual instability. Radiographic examination showed bone metaplasia involving the anterior and medial sides of the joint in 5 patients. HEF presented several advantages: it improves elbow stability and it avoids long and demanding surgery in particular in cases with large soft tissue damage. We therefore consider elbow HEF to be a viable option for treating R-M type I and II fracture-dislocations.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。