Reverse shoulder arthroplasty with a 155° neck-shaft angle inlay implant design without reattachment of the subscapularis tendon results in satisfactory functional internal rotation and no instability: a cohort study

采用155°颈干角内嵌式假体设计的反向肩关节置换术,无需重新连接肩胛下肌腱,即可获得令人满意的功能性内旋,且无不稳定性:一项队列研究

阅读:2

Abstract

BACKGROUND: The aim of this study was to use the Activities of Daily Living which require Internal Rotation (ADLIR) questionnaire to assess the functional internal rotation in patients who had undergone reverse shoulder arthroplasty (RSA) without reattachment of the subscapularis (SSc) tendon at a minimum follow-up of 2 years. The secondary aim was to report the objective range of motion (ROM) and the rate of postoperative instability. MATERIALS AND METHODS: All consecutive primary RSA procedures without reattachment of the SSc tendon that were performed using a Delta Xtend prosthesis (an inlay system with a 155° neck-shaft angle) between January 2015 and December 2020 were identified to ensure a minimum follow-up of 2 years. Patients were contacted and requested to fill in several questionnaires, including the ADLIR and Auto-Constant scores. RESULTS: In total, 210 patients met the inclusion criteria; among those patients, 187 could be contacted and 151 completed questionnaires (response rate: 81%). The SSc tendon was fully detached without repair in all cases, and a superolateral approach was used in 130 (86%) cases. The median follow-up was 4.5 years (range: 2.0-7.6). At final follow-up, the mean ADLIR score was 88/100 (interquartile range (IQR): 81-96). The median level reached in internal rotation was the 3rd lumbar vertebra (IQR: lumbosacral region-12th thoracic vertebra). Of the 210 eligible patients, one required a revision for a dislocation within the first month after primary surgery. With regards to regression analysis with ADLIR score as the outcome, none of the factors were associated with the ADLIR score, although age and smoking approached significance (0.0677 and 0.0594, respectively). None of the explanatory variables were associated with ROM in internal rotation (p > 0.05). CONCLUSIONS: This study demonstrates that satisfactory ADLIR scores and internal rotation ROM were obtained at mid-term follow-up after RSA leaving the SSc detached. Leaving the SSc detached also did not lead to high instability rates; only one out of 210 prostheses was revised for dislocation within the first month after primary surgery.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。