Both fractional exhaled nitric oxide and sputum eosinophil were associated with uncontrolled asthma

呼出气一氧化氮分数和痰嗜酸性粒细胞均与哮喘控制不佳相关。

阅读:2

Abstract

BACKGROUND: Sputum eosinophil and fractional exhaled nitric oxide (FeNO), noninvasive biomarkers of local eosinophilic airway inflammation, can be used to assess asthma outcome. Nevertheless, the clinical application of the association between FeNO and sputum eosinophil is controversial. The aim of the study was to investigate the predictive relationship between FeNO and sputum eosinophil in uncontrolled asthmatic patients and the correlation between sputum eosinophil and FeNO in bronchial reversibility and bronchial hyperresponsiveness (BHR). METHODS: A total of 69 uncontrolled asthmatic patients were included in the study. All patients underwent a clinical assessment on the same day as follows: FeNO, spirometry with BHR or bronchodilator reversibility test and induced sputum in turn. Eosinophilic airway inflammation was defined as sputum eosinophil percentage (≥2.5%)/FeNO level (≥32 parts per billion [ppb]). RESULTS: FeNO level and sputum neutrophilic percentage were higher in the sputum eosinophilia group compared to those without (49 versus 27, p=0.011; 71.12 versus 87.67, p=0.012, respectively). Sputum eosinophil percentage was higher with raised FeNO level compared to those without (10.3% versus 2.75%, p=0.03). A significant correlation was observed between sputum eosinophil percentage and FeNO level (r=0.4016; p=0.0006). There were no significant relationships between sputum eosinophilic percentage and provocative dose (PD(20))/ΔFEV(1) (improvement in a forced expiratory volume in 1 second [FEV(1)] after 400μg of salbutamol), FeNO levels and PD(20)/ΔFEV(1). The FeNO level of 35.5 ppb was effective in assessing sputum eosinophilia, with a receiver operating characteristic area under curve (AUC) of 0.707 (p=0.011; 95% confidence interval [CI] 0.573-0.841), and 4.36% was the best diagnostic cutoff value of sputum eosinophil percentage for the FeNO level of 32 ppb (AUC 0.721; 95% CI 0.59-0.852). CONCLUSION: FeNO level can accurately detect eosinophilic asthma but has limited value to assess noneosinophilic asthma in uncontrolled stage. Further studies are required to validate the use of FeNO level to determine an optimal cutoff for sputum eosinophilia that could be used in clinical practice.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。