Microform Calibration Uncertainties of Rockwell Diamond Indenters

洛氏金刚石压头的微形校准不确定度

阅读:1

Abstract

National and international comparisons in Rockwell hardness tests show significant differences. Uncertainties in the geometry of the Rockwell diamond indenters are largely responsible for these differences. By using a stylus instrument, with a series of calibration and check standards, and calibration and uncertainty calculation procedures, we have calibrated the microform geometric parameters of Rockwell diamond indenters. These calibrations are traceable to fundamental standards. The expanded uncertainties (95 % level of confidence) are ±0.3 μm for the least-squares radius; ±0.01° for the cone angle; and ±0.025° for the holder axis alignment calibrations. Under ISO and NIST guidelines for expressing measurement uncertainties, the calibration and uncertainty calculation procedure, error sources, and uncertainty components are described, and the expanded uncertainties are calculated. The instrumentation and calibration procedure also allows the measurement of profile deviation from the least-squares radius and cone flank straightness. The surface roughness and the shape of the spherical tip of the diamond indenter can also be explored and quantified. Our calibration approach makes it possible to quantify the uncertainty, uniformity, and reproducibility of Rockwell diamond indenter microform geometry, as well as to unify the Rockwell hardness standards, through fundamental measurements rather than by performance comparisons.