Abstract
OBJECTIVE: To document laryngeal framework rupture following voluntary cough-holding as an airway complication of donning a personal protective equipment suit that was too small in size. METHODS: Clinical record and literature review, with proposition of plausible aerodynamics of the airway injury. RESULTS: Whilst carrying out his duty in the coronavirus disease ward, a resident attempted to stifle a paroxysm of cough when wearing a personal protective equipment suit that was too small with his neck flexed and restricted. There was a sudden release of pressure, intense pain and swelling in the neck with crepitus. Imaging revealed a non-displaced fracture in the lower end of the partially ossified right thyroid lamina, a cricothyroid membrane tear and subcutaneous emphysema. The symptoms resolved gradually on conservative management. CONCLUSION: This report underlines the importance of donning appropriately sized personal protective equipment and encouraging its proper use amongst coronavirus disease 2019 caregivers. Non-traumatic laryngeal injury, itself a rare event, has never been reported as a posture-related complication of wearing personal protective equipment.