Unintentional error in formula preparation and its simulated impact on infant weight and adiposity

配方奶粉冲调过程中的无意错误及其对婴儿体重和脂肪堆积的模拟影响

阅读:1

Abstract

BACKGROUND: Accelerated weight gain in infancy is a public health issue and is likely due to feeding behaviours. OBJECTIVES: To test the accuracy of individuals to dispense infant formula as compared with recommended serving sizes and to estimate the effect of dispensing inaccuracy on infant growth. METHODS: Fifty-three adults dispensed infant formula powder for three servings of 2, 4, 6, and 8 fl oz bottles, in random order. The weight of dispensed infant formula powder was compared with the recommended serving size weight on the nutrition label. A novel mathematical model was used to estimate the impact of formula dispensing on infant weight and adiposity. RESULTS: Nineteen percent of bottles (20 of 636) prepared contained the recommended amount of infant formula powder. Three percent were underdispensed, and 78% of bottles were overdispensed, resulting in 11% additional infant formula powder. Mathematical modelling feeding 11% above energy requirements exclusively for 6 months for male and female infants suggested infants at the 50th percentile for weight at birth would reach the 75th percentile with increased adiposity by 6 months. CONCLUSIONS: Inaccurate measurement of infant formula powder and overdispensing, which is highly prevalent, specifically, may contribute to rapid weight gain and increased adiposity in formula-fed infants.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。