Diagnostic accuracy of anti-phospholipase A2 receptor (PLA2R) antibodies in idiopathic membranous nephropathy: an Italian experience

抗磷脂酶A2受体(PLA2R)抗体在特发性膜性肾病诊断中的准确性:意大利的经验

阅读:1

Abstract

BACKGROUND: Autoantibodies against-phospholipase A2 receptor (PLA2R) are specific markers of idiopathic membranous nephropathy (iMN). Enzyme-linked immunosorbent assay (ELISA) is becoming the preferred method in many laboratories for the determination of anti-PLA2R antibodies, because it provides quantitative results, and is not prone to subjective interpretation, as is the case with indirect immunofluorescence assay. METHODS: The purpose of our study was to determine the diagnostic performance of serum PLA2R antibodies detected by commercially available ELISA in a large Italian multicenter cohort of patients with biopsy-proven iMN and in patients with other renal diseases, with special focus on evaluating the optimal cut-off value to discriminate positive and negative results. A total of 495 consecutive patients were recruited. Renal biopsies were performed in all patients, and blood samples were taken before the initiation of immunosuppressive treatment. RESULTS: According to the clinical diagnosis and to kidney biopsy, 126 patients were diagnosed with iMN and 369 had other non-membranous nephropathies. Anti-PLA2R autoantibodies were detected using a commercial anti-PLA2R ELISA. At a cut-off value of 20 relative units (RU)/ml indicated by the manufacturer for positive classification, sensitivity was 61.1% and specificity 99.7%. At a cut-off value of 14 RU/ml indicated by the manufacturer for borderline results, sensitivity was 63.5% and specificity remained the same (99.7%). At a cut-off of 2.7 RU/ml, selected as the optimal cut-off on the basis of ROC curve analysis, sensitivity was 83.3% and specificity 95.1%. The best overall efficiency of the test was observed at 2.7 RU/ml; however, the highest positive likelihood ratio and diagnostic odds ratio were achieved at 14 RU/ml. A cut-off threshold higher than 14 RU/ml or lower than 2.7 RU/ml entailed worse test performance. CONCLUSION: Depending on the clinical use (early diagnosis or as a support to confirm clinical diagnosis), nephrologists may take advantage of this evidence by choosing the most convenient cut-off. However, renal biopsy remains mandatory for the definitive diagnosis of iMN and for the assessment of disease severity.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。