Changes in skin temperature and behaviors of preweaning Holstein calves in a hot environment monitored by a multimodal tail-attached device

利用多模式尾部连接装置监测高温环境下断奶前荷斯坦小牛的皮肤温度变化和行为变化

阅读:2

Abstract

This study aimed to determine the applicability of a tail-attached device in monitoring animal-based indicators (ABI) associated with changes in environmental conditions in calves through investigating the relationship between sensor-derived ABI and the temperature-humidity index (THI). Furthermore, to identify effective ABI indicative of heat stress status, sensor-derived ABI of calves under differing heat stress levels based on rectal temperature (RT) were compared. The tail-attached device, which is capable of measuring skin temperature (ST), activity intensity, and roll angle along the longitudinal axis of the tail at 3-min intervals, was attached to 99 preweaning female Holstein calves for an average of 4 wk (26.4 ± 6.8 d). After selecting data from mild to hot days (daily average THI of ≥55), physiological (daily maximum tail ST) and behavioral (daily average activity intensity, daily total lying time, and daily total body position change) ABI were computed, and their relationship with the daily average THI was determined using piecewise regression analysis. Additionally, during the hot season, RT of 20 randomly selected tested calves were measured thrice a week (every 2.4 ± 0.5 d), and a comparison was conducted between the ABI of calves with normal RT (<39.5°C) and those with high RT (≥39.5°C), utilizing data from days characterized by potential heat stress (daily average THI of ≥75). During the study, ambient temperature (°C) and relative humidity (%) were recorded every 10 min using an automatic digital data logger, from which the daily average THI was calculated. Piecewise regression analysis identified THI breakpoints of 73.6 for tail ST, 79.1 for average activity intensity, 72.3 for lying time, and 79.1 for position change. All the tested ABI tended to increase as THI increased, and this trend was pronounced in tail ST, activity intensity, and position change after the breakpoint. These 3 ABI were higher in calves with high RT compared with those with normal RT, whereas lying time shared similar values between the RT groups. Overall, these findings suggest that the tail-attached device can simultaneously monitor both physiological and behavioral ABI in calves, and among the ABI, tail ST, activity intensity, and position change are the effective ABI indicative of heat stress status.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。