Impact of pretransplant T2DM on left ventricular deformation and myocardial perfusion in heart transplanted recipients: a 3.0 T cardiac magnetic resonance study

移植前2型糖尿病对心脏移植受者左心室形变和心肌灌注的影响:一项3.0T心脏磁共振研究

阅读:1

Abstract

BACKGROUND: Pretransplant type 2 diabetes mellitus (T2DM) is associated with increased cardiovascular and all-cause mortality after heart transplant (HT), but the underlying causes of this association remain unclear. The purpose of this research was to examine the impact of T2DM on left ventricular (LV) myocardial deformation and myocardial perfusion following heart transplantation using cardiovascular magnetic resonance imaging. METHODS: We investigated thirty-one HT recipients with pretransplant T2DM [HT(DM+)], thirty-four HT recipients without pretransplant T2DM [HT(DM-)] and thirty-six controls. LV myocardial strains, including the global longitudinal, radial, and circumferential strain (GLS, GRS and GCS, respectively), were calculated and compared among groups, as were resting myocardial perfusion indices, which included time to peak myocardial signal intensity (TTM), maximum signal intensity (MaxSI), and Upslope. The relationships between LV strain parameters or perfusion indices and biochemical indicators were determined through Spearman's analysis. The impact of T2DM on LV strains in HT recipients was assessed using multivariable linear regression analyses with backward stepwise selection. RESULTS: In the HT(DM+) group, the LV GLS, GRS, and GCS exhibited significantly lower magnitudes than those in both the HT(DM-) and control groups. TTM was higher in the HT(DM+) group than in both the HT(DM-) and control groups, while no significant differences were observed among the groups regarding Upslope and MaxSI. There was a negative correlation between glycated hemoglobin and the magnitude of strains (longitudinal, r = - 0.399; radial, r = - 0.362; circumferential, r = - 0.389) (all P < 0.05), and a positive correlation with TTM (r = 0.485, P < 0.001). Regression analyses that included both pretransplant T2DM and perfusion indices revealed that pretransplant T2DM, rather than perfusion indices, was an independent determinant of LV strain (β = longitudinal, - 0.508; radial, - 0.370; circumferential, - 0.371) (all P < 0.05). CONCLUSION: In heart transplant recipients, pretransplant T2DM has a detrimental effect on subclinical left ventricular systolic function and could potentially impact myocardial microcirculation following HT.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。