The impact of age on comparative diagnostic accuracy of temporal artery thermometers and non-contact infrared thermometers for fever detection: a systematic review and meta-analysis

年龄对颞动脉温度计和非接触式红外温度计在发热检测中诊断准确性的影响:系统评价和荟萃分析

阅读:2

Abstract

BACKGROUND: Non-invasive temporal artery thermometers (TATs) and non-contact infrared thermometers (NCITs) are increasingly used in community settings to measure body temperature. Existing research predominantly focuses on pediatric populations, yet the accuracy and precision of TATs and NCITs for fever screening across age groups remain unclear. This study aims to assess age-related differences in the diagnostic accuracy of TATs and NCITs for fever detection. METHODS: A systematic review and meta-analysis were conducted, sourcing data from PubMed, MEDLINE, CINAHL, EMBASE, Cochrane Library, ProQuest, and Web of Science. Prospective studies comparing TATs and NCITs against body temperature measurement methods were included. Two independent researchers extracted data, and study quality was assessed with the QUADAS-2 tool. Pooled estimates of sensitivity, specificity, and the hierarchical summary area under the receiver operating characteristic (ROC) curves were calculated using STATA version 17. RESULTS: This meta-analysis included 34 studies with 28,996 participants, of whom 5,358 were febrile. For TATs, 22 studies with 9,894 readings yielded a pooled sensitivity of 0.59 (95% CI: 0.40-0.76) and specificity of 0.91 (95% CI: 0.83-0.96). Sensitivity was higher at fever thresholds > 38 °C (0.71, 95% CI: 0.60-0.80), and higher in children (0.77, 95% CI: 0.66-0.85) than in adults (0.48, 95% CI: 0.30-0.67). Similar sensitivities were observed between rectal and other standards (0.70, 95% CI: 0.59-0.80 vs. 0.70, 95% CI: 0.41-0.89). For NCITs, 16 studies with 14,234 readings yielded a pooled sensitivity of 0.70 (95% CI: 0.54-0.82) and specificity of 0.94 (95% CI: 0.90-0.97). Sensitivity improved at fever thresholds > 38 °C (from 0.70 to 0.75, 95% CI: 0.55-0.88) and was higher in children compared to the overall estimate (0.79 vs. 0.70, 95% CI: 0.62-0.90). Comparable sensitivities were noted between axillary and other standards (0.73, 95% CI: 0.30-0.94 vs. 0.75, 95% CI: 0.49-0.90). CONCLUSIONS: TATs and NCITs show variable diagnostic accuracy across age groups, with higher sensitivity in children and at elevated fever thresholds. This variability underscores the importance of age-specific use of these thermometers and highlights the need for further research to optimize diagnostic performance across populations.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。