Diagnostic accuracy of the Xpert(®) MTB/XDR assay for detection of Isoniazid and second-line antituberculosis drugs resistance at central TB reference laboratory in Tanzania

坦桑尼亚中央结核病参考实验室使用 Xpert® MTB/XDR 检测异烟肼和二线抗结核药物耐药性的诊断准确性

阅读:3

Abstract

INTRODUCTION: Early diagnosis of tuberculosis (TB) and universal access to drug-susceptibility testing (DST) are critical elements of the WHO End TB Strategy. Current rapid tests (e.g., Xpert(®) MTB/RIF and Ultra-assays) can detect rifampicin resistance-conferring mutations, but cannot detect resistance to Isoniazid and second-line anti-TB agents. Although Line Probe Assay is capable of detecting resistance to second-line anti-TB agents, it requires sophisticated laboratory infrastructure and advanced skills which are often not readily available in settings replete with TB. A rapid test capable of detecting Isoniazid and second-line anti-TB drug resistance is highly needed. METHODS: We conducted a diagnostic accuracy study to evaluate a new automated Xpert MTB/XDR 10-colour assay for rapid detection of Isoniazid and second-line drugs, including ethionamide, fluoroquinolones, and injectable drugs (Amikacin, Kanamycin, and Capreomycin). Positive Xpert MTB/RIF respiratory specimens were prospectively collected through routine diagnosis and surveillance of drug resistance at the Central TB Reference Laboratory in Tanzania. Specimens were tested by both Xpert XDR assay and LPA against culture-based phenotypic DST as the reference standard. FINDINGS: We analysed specimens from 151 TB patients with a mean age (SD) of 36.2 (12.7) years. The majority (n = 109, 72.2%) were males. The sensitivity for Xpert MTB/XDR was 93.5% (95% CI, 87.4-96.7); for Isoniazid, 96.6 (95% CI, 92.1-98.6); for Fluoroquinolone, 98.7% (95% Cl 94.8-99.7); for Amikacin, 96.6%; and (95% CI 92.1-98.6) for Ethionamide. Ethionamide had the lowest specificity of 50% and the highest was 100% for Fluoroquinolone. The diagnostic performance was generally comparable to that of LPA with slight variations between the two assays. The non-determinate rate (i.e., invalid M. tuberculosis complex detection) of Xpert MTB/XDR was 2·96%. CONCLUSION: The Xpert MTB/XDR demonstrated high sensitivity and specificity for detecting resistance to Isoniazid, Fluoroquinolones, and injectable agents. This assay can be used in clinical settings to facilitate rapid diagnosis of mono-isoniazid and extensively drug-resistant TB.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。