Monitoring levodopa oxidation and reduction reactions using surface plasmon resonance on a nanohole array electrode

利用纳米孔阵列电极上的表面等离子体共振监测左旋多巴的氧化还原反应

阅读:1

Abstract

The traditional method of monitoring the oxidation and reduction of biomedical materials usually relies on electrochemical (EC) measurement techniques. Here, we demonstrate a surface plasmon resonance (SPR) method to monitor the oxidation process. Using levodopa L-dopa as the target analyte, a nanohole sensing plate is embedded in the EC electrode to enhance the oxidation signal and generate SPR. Cyclic voltammetry (CV) measurement was first conducted to understand the baseline of EC response of L-Dopa. Then, the redox reactions were simultaneously monitored through SPR measurements during the CV voltage scan. The results showed that the limit of detection using traditional CV reached 1.47 μM while using EC-SPR, the limit of detection improved to 1.23 μM. Most importantly, we found a strong correlation between CV current profiles and the SPR reflection spectra. Our results facilitate detecting electrochemical reactions using an optical probing method.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。