A Randomised Controlled Trial Comparing the Pharmacokinetics and Tolerability of the Proposed Adalimumab Biosimilar MSB11022 Delivered via Autoinjector and Pre-filled Syringe in Healthy Subjects

一项随机对照试验比较了拟开发的阿达木单抗生物类似药 MSB11022 通过自动注射器和预充式注射器在健康受试者中的药代动力学和耐受性

阅读:2

Abstract

INTRODUCTION: The aim of the study was to demonstrate the bioequivalence, and compare the safety and tolerability of MSB11022, a proposed biosimilar of adalimumab, when delivered by either an autoinjector (AI) or a pre-filled syringe (PFS). METHODS: In this pharmacokinetic (PK), parallel group, open-label study, 216 healthy volunteers were randomised 1:1 to receive a single subcutaneous injection of a 40 mg/0.8 mL dose of MSB11022 administered via AI or PFS. Coprimary PK endpoints were maximum observed concentration (C(max)), area under the concentration-time curve (AUC) from time 0 to the last quantifiable concentration (AUC(0-t)), and AUC from time 0 extrapolated to infinity (AUC(0-inf)). PK equivalence between the AI and PFS administration methods was declared if the 90% confidence intervals (CIs) for the ratio of geometric least square means was entirely contained within the 80-125% equivalence margin for all coprimary endpoints. Safety and tolerability were also evaluated. RESULTS: The 90% CI for the three coprimary PK endpoints (C(max), AUC(0-t) and AUC(0-inf)) were entirely contained within the predefined equivalence margins of 80-125%. Mean serum concentration-time profiles were similar following injection via AI or PFS. Treatment-emergent adverse events (TEAEs) were comparable across both treatment groups. Study device-related TEAEs were reported by 11.3% and 13.1% of subjects in the AI and PFS treatment groups, respectively. Study drug-related TEAEs were reported by 28.3% and 34.6% of subjects in the AI and PFS treatment groups, respectively. Few subjects experienced injection-site reactions, mainly pain and erythema, regardless of the administration method. CONCLUSION: Delivery of MSB11022 via an AI is bioequivalent to delivery via a PFS. The safety and tolerability profile of MSB11022 was comparable across administration methods. The development of an AI for MSB11022 provides a choice of self-injection devices available to patients, potentially improving treatment compliance. TRIAL REGISTRATION: ClinicalTrials.gov trial identifier: NCT04018599.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。