Safety and effectiveness of blind percutaneous liver biopsy: analysis of 1412 procedures

盲穿经皮肝穿刺活检的安全性和有效性:1412例手术分析

阅读:1

Abstract

BACKGROUND: Percutaneous liver biopsy is one of the most important and widely used methods for diagnosing chronic liver diseases; however, controversies related to the potential risk of complications and patient discomfort still exist. OBJECTIVES: The objective of this study was to evaluate the safety and success rate of blind percutaneous liver biopsy. PATIENTS AND METHODS: We conducted a retrospective analysis of 1412 blind percutaneous thick-needle liver biopsies performed during 1977-2000 at a single center on 1110 patients, using archived medical data of the center. RESULTS: The overall success rate of obtaining a liver sample with this method was 95.3%. Of all the samples assessed, 91.7% were determined to be fully representative for an evaluation by the pathologist. Complications occurred in 259 procedures (18.3%). While no fatalities associated with liver biopsy were noted, 9 serious complications (0.64%) directly related to biopsies were reported. Pain was the most common complication (15.3%). Significantly more complications (pain and vasovagal reactions) were reported in females (22.1%) than in males (16.1%) (P = 0.005). The rate of complications was significantly correlated with the stage of fibrosis (P = 0.027), i.e. the higher the fibrosis stage, the higher the complication rate. Previous surgical procedures involving the abdominal cavity or thorax influenced the effectiveness of liver biopsy (P = 0.017). Less operator experience was significantly associated with a higher rate of procedure failure (P = 0.002). Statistical significance of the relationship between individual operator efficiency and complication rate (P = 0.000) and that between individual operator efficiency and biopsy failure rate (P = 0.002) was observed. CONCLUSIONS: Blind percutaneous liver biopsy is a safe and effective invasive procedure, despite the fact that noninvasive fibrosis assessment methods are currently widely available and used instead of histological evaluation. Complications risk and failure rate are low if indications and contraindications are considered carefully and the biopsy is performed by a skilled and experienced operator. Certain groups of patients may benefit from an image-guided procedure to improve its effectiveness.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。