Patterns in continuous pulse oximetry data prior to pulseless electrical activity arrest in the general care setting

一般护理环境中无脉性电活动停止前连续脉搏血氧饱和度数据的模式

阅读:1

Abstract

The study objective was to understand if features derived from continuous pulse oximetry data can provide advanced warning of pulseless electrical activity arrest in the general care inpatient setting. Retrospective analysis of SpO2 and pulse rate data derived from continuous pulse oximetry was performed for pulseless electrical activity (n = 38) and control (n = 42) patient cohorts. Measures of central tendency and variation over time intervals ranging from 1 min to 1 h were used for inter- and intra-group comparisons. Logistic regression was applied to understand ability of features to predict pulseless electrical activity in future time intervals. Overall, the pulseless electrical activity arrest group tended to have lower mean SpO2 and higher mean pulse rate values than the control group. SpO2 and pulse rate variability was higher in the pulseless electrical activity arrest cohort. Changes in variability were observed beginning several hours prior to the rescue event. Up to 20 min before rescue events, pulse rate features were significantly different from feature values for the preceding 30-min interval (> 10% difference in mean, > 46% difference in range). Similar results were found for SpO2 features 10 min before the event (> 4% difference in mean, > 60% difference in range). There is a significant difference in SpO2 and pulse rate features derived from continuous pulse oximetry between pulseless electrical activity and control groups. Integration of automated feature calculation and clinician notification into clinical monitoring and information systems may increase patient safety by supporting early detection of such events.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。