Abstract
PURPOSE: To investigate the application value of "electronic alerts" ("e-alerts") for acute kidney injury (AKI) among high-risk wards of hospitals. METHODS: A prospective, randomized, controlled study was conducted. We developed an e-alert system for AKI and ran the system in intensive care units and divisions focusing on cardiovascular disease. The e-alert system diagnosed AKI automatically based on serum creatinine levels. Patients were assigned randomly to an e-alert group (467 patients) or non-e-alert group (408 patients). Only the e-alert group could receive pop-up messages. RESULTS: The sensitivity, specificity, Youden Index and accuracy of the AKI e-alert system were 99.8, 97.7, 97.5 and 98.1%, respectively. The prevalence of the diagnosis for AKI and expanded-AKI (AKI or multiple-organ failure) in the e-alert group was higher than that in the non-e-alert group (AKI 7.9 and 2.7%, P = 0.001; expanded-AKI 16.3 and 6.1%, P < 0.001). The prevalence of nephrology consultation in the e-alert group was higher than that in the non-e-alert group (9.0 and 3.7%, P = 0.001). There was no significant difference in the prevalence dialysis, rehabilitation of renal function or death in the two groups. CONCLUSION: The e-alert system described here was a reliable tool to make an accurate diagnosis of AKI.