Carbon dioxide gas embolism during robot-assisted laparoscopic partial nephrectomy

机器人辅助腹腔镜部分肾切除术中二氧化碳气体栓塞

阅读:1

Abstract

INTRODUCTION: One of the complications of laparoscopic surgery is gas embolism, which has low incidence but high mortality. Carbon dioxide embolism diagnosed during robot-assisted laparoscopic partial nephrectomy has been experienced. CASE PRESENTATION: 77-year-old woman with a left renal tumor received robot-assisted laparoscopic partial nephrectomy. End-tidal carbon dioxide pressure and oxygen saturation of peripheral artery suddenly decreased 5 min after the start of tumor resection with pneumoperitoneum pressure of 15 mmHg and positive end-expiratory pressure turned off. Therefore, pulmonary artery gas embolism was diagnosed. The pneumoperitoneum pressure was dropped, and positive end-expiratory pressure was restarted. These conditions improved and the procedure was completed. CONCLUSION: Carbon dioxide gas embolism during robot-assisted partial nephrectomy should be focused on because prompt diagnosis and treatment will improve life outcomes. The optimal pneumoperitoneum pressure for each case, rather than making it uniform, should be reconsidered.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。